ELECTRIC WIRING
The electric wiring must be performed by a specialised electrician fully respecting current standards and
legislation in force.
Check that the power supply corresponds to the voltage requested by the hood, which is given on
the silver label stuck inside the hood.
Ensure that the wiring system conforms to current standards and the earth discharge works efficiently.
Pay special attention to the hood power cable, ensure that it does not pass through any holes without a
cable clamp.
For direct connection to the electrical mains is necessary to provide a device that ensures disconnection
from the electrical mains, with an opening distance of the contacts that allows the complete disconnection
under the conditions ofovervoltage category III, in accordance with the rules of installation.
The plug or omnipolar switch must be accessible when the unit is installed
If the power cord is damaged, it must be replaced by a special cord or assembly available from the manu-
facturer or its service agent. The cable used must be of type H05VV-F 3 x 0.75 mm2 minimum cross-
section.
The manufacturer declines all responsibility if the current accident prevention standards in force
are not respected, which are needed for the wiring system to operate correctly
CONTROL
DIGITAL CONTROLS
In this version there are four soft touch buttons and a display
> One button for turning on at 2nd speed and for turning the motor off.
> Two buttons + and - for increasing and decreasing the motor speed.
> A TIMER button for turning the motor off after 10 minutes.
When the timer is activated, the number on the display flashes.
Special functions:
After 100 hours use, a 0 or a letter A will start flashing on the DISPLAY to
remind the user to clean the metal filters.
After washing the metal filters, reset the hour meter by pressing the TIMER
button for more than three seconds with the hood turned off.
When the hour meter has been reset a dash appears on the display, with
the hood turned off.