Product Specific Instructions
Warning
WARNING Polymer hazard
The vanes in this product contain PTFE (a synthetic flu-
oropolymer). Due to wear, there might be PTFE parti-
cles inside the product. Heated PTFE can produce fumes
which may cause polymer fume fever with flu-like
symptoms, especially when smoking contaminated to-
bacco.
Health and Safety recommendations for PTFE must be
followed when handling vanes and other components:
Do not smoke when servicing this product
PTFE-particles must not come in contact with open
fire, glow or heat
Motor components must be washed with cleaning
fluid and not blown clear with an air line
Wash your hands before starting any other activity
Rotation
WARNING Never run the motor without the restric-
tion plates in place!
The restriction plates must be assembled on the engine
in order for ATEX to be valid. If the restriction plates
are removed, the motor will become overheated when in
use.
Restrictors
To achieve clockwise (CW) or counter clockwise (CCW) ro-
tation, mount selected restrictor plates at the inlet/ outlet
ports A and B. For reversible rotation (Rev) mount restrictor
plates at the inlet port C and at the outlet ports A and B.
© Atlas Copco Industrial Technique AB - 9834 4049 00
Installation diagram
Reversible motor
Installation diagram
Non-Reversible motor
Shaft load diagram
Hot Spots
The following hotspots on the air motor can reach high tem-
peratures during operation:
• motor housing
• seal ring at the output shaft
The highest temperatures occur when the air motor is run-
ning at full pressure without load. With increasing torque, the
air motor reduces the rotational speed and the temperature.
Warning