Operating Instructions

Basic Operations

Follow the instructions below to operate and program the Ethereal LED Module.
English
The LED Module turns on automatically when power is connected, and
turns off when power is cut.
When power is resumed, the LED Module will restore to the previous saved setting
automatically, whether it was last set at Manual, Preset or Automatic Mode, and the intensity
level of all the LED channels.
The fan on the Ethereal fixture is tempereature controlled.
The Ethereal LED Lighting System has a built-in temperature control system. The fan will be
automatically engaged when the temperature is above 40°C/160°F, and disengage when it is
below 35°C/95°F.
If the fan fails, the system may overheat and the system will enter fail-safe mode when the
temperature is above 70°C/158°F, turning off all channels and the RGB Mood Light will be
blinking red light. The system will exit fail-safe mode and resume normal operation when the
temperature drops below 65°C/149°F.
The fan on the Ethereal fixture is tempereature controlled.
The Ethereal LED Lighting System requires the Maxspect ICV6 controller for remote control
through Android/iOS devices. When a stand-alone Ethereal fixture is used without the ICV6
controller, it can be controlled by the control dial for basic functionality.
Note
For instructions on ICV6 controller and the Android/iOS app, please refer to the embedded
user manual within the app.