8962235
5.
Power remains on after the Test Button is pressed. Follow these
steps to resolve the issue.
a.
Press the Test Button again to confirm it was activated.
b.
Check the tester light code to see if it indicates the issue. Take
steps to fix the indicated problem.
•
If using a device, stop the generator and disconnect the
device. Plug the device into a working outlet to confirm
the device is not the problem.
c.
Consult with a qualified electrician to replace the faulty GFCI
outlet with a new GFCI outlet.
CLEAN THE GENERATOR
Consult the engine manual for instructions before you begin cleaning
the generator. Improper cleaning methods may damage the engine.
1.
Unplug all equipment connected to the generator.
2.
Disconnect the battery and set aside to avoid water.
3.
Clean the generator using a well rung-out hand cloth, taking care
when cleaning the control panel to avoid damaging any seals.
4.
Allow the generator to air dry before reconnecting battery and
starting it up.
DISPOSAL
Recycle a tool damaged beyond repair at the appropriate facility.
Contact your local municipality for a list of disposal facilities or by-laws
for electronic devices, batteries, oil or other toxic liquids.
DO NOT pollute the environment by allowing uncontrolled discharge of
waste oil.
TROUBLESHOOTING
Visit a Princess Auto Ltd. location for a solution if the tool does not
function properly or parts are missing. If unable to do so, have a
qualified technician service the tool.
www.princessauto.com / 1-800-665-8685
GASOLINE GENERATOR
V1.0
Page 12