Eisbecher 2 Aurora Glas Alphacool International GmbH V. 5.00–02.2021 Deutsch ............................................................Sicherheitshinweise ........................................................ 4 Montagematerial ........................................................4 Montage Eisbecher 2 Aurora Glas ..................................................5 Towermontage: ........................................................6 Radiatormontage: ....................................................... 7 Anschluss Möglichkeiten: ....................................................8 aRGB Anschluss: ......................................................... 9 English ............................................................10 Safety Instructions ........................................................
Page 3
Alphacool International GmbH Eisbecher 2 Aurora Glas avis général de sécurité ....................................................... 16 Matériel de Assemblée ......................................................16 Assemblée Eisbecher 2 Aurora Glass ................................................17 Assemblage de logements: ..................................................... 18 Montage de radiateurs: ....................................................19 Options de connexion: ....................................................20...
Eisbecher 2 Aurora Glas Alphacool International GmbH Sicherheitshinweise Lesen Sie die Sicherheitshinweise, bevor Sie mit der Installation beginnen. Montagematerial Das Steigrohr 140mm liegt nur im Eisbecher Aurora 250mm bei. 4x M3x5 12x M4x8 4x M4x12 4x M4 2x Lüfterhalterung 1x Steigrohr 140mm 2x 120 Lüfterhalterung...
Alphacool International GmbH Eisbecher 2 Aurora Glas Montage Eisbecher 2 Aurora Glas Haltermontage: Steigrohr Positionen: Entfernen Sie die Pumpe und Standhalterung, schrauben Sie die hier rot markierten Halterschrauben raus. Ziehen Sie den Deckel mit Gestänge und anschließend das Glasrohr vorsichtig heraus.
Eisbecher 2 Aurora Glas Alphacool International GmbH Towermontage: Inlay Position: Achten Sie darauf, dass der Filter mit dem Inlay immer oben links positioniert ist. Nur in dieser Nutzen Sie dafür die vier M4x8 Schrauben in Verbindung mit den M4 Muttern. Je Position ist der Wasserfluss gewährleistet.
Alphacool International GmbH Eisbecher 2 Aurora Glas Radiatormontage: Radiator Beispiel: 120-30 und 140-30 X-Flow. Bei diesem Beispiel brauchen die Verwenden Sie für die Radiatormontage die vier M3x5 Schrauben. Beachten Sie das Halter nicht gedreht werden. je nach Radiatorgröße wie im Beispiel 240-30 und 280-30 X-Flow die Halterung...
Eisbecher 2 Aurora Glas Alphacool International GmbH Anschluss Möglichkeiten: Fillport Fillport Wir empfehlen ausschließlich klare Kühlflüssigkeiten aus unserer eigenen Produktion (CKC, Tec Protect oder Eiswasser Crystal – kein UV“!) oder reines Verschlauchen Sie den Eisbecher nach Ihren Wünschen. Die Beispiele zeigen einige destiliertes bzw.
Alphacool International GmbH Eisbecher 2 Aurora Glas aRGB Anschluss: Anschluss Eisbecher 2 Aurora Glas SATA Power Optional: Alphacool Aurora Eiscontrol (Art.-Nr. 15360)
English Eisbecher 2 Aurora Glas Alphacool International GmbH English Safety Instructions Read the safety instructions before starting the installation. Assembly material The 140mm riser pipe is only included in the Eisbecher Aurora 250mm. 4x M3x5 12x M4x8 4x M4x12 4x M4...
Alphacool International GmbH Eisbecher 2 Aurora Glas English Assembly Eisbecher 2 Aurora Glas Bracket assembly: Rising pipe positions: Remove the pump and stand bracket, unscrew the holder screws marked in red. Carefully pull out the cover with linkage and then the glass tube. Replace the desired riser tube.
English Eisbecher 2 Aurora Glas Alphacool International GmbH Tower assembly: Inlay Position: Make sure that the filter with the inlay is always positioned on the top left. Only in this position is the Use the four M4x8 screws in conjunction with the M4 nuts. Depending on the water flow guaranteed.
Alphacool International GmbH Eisbecher 2 Aurora Glas English Radiator assembly: Radiator example: 120-30 and 140-30 X-Flow. In this example, the holders do not Use the four M3x5 screws for mounting the radiator. need to be rotated. Note: That depending on the radiator size, as in the example 240-30 and 280-30 X-...
Eisbecher 2 Aurora Glas Alphacool International GmbH Connection options: Fillport Fillport We recommend only clear cooling liquids from our own production (CKC, Tec Protect or Eiswasser Crystal - no UV"!) or pure distilled or osmosis filtered water Connect the tubing to the Reservoir as you wish.
Alphacool International GmbH Eisbecher 2 Aurora Glas aRGB Connection: Connection Eisbecher 2 Aurora Glas SATA Power Optional: Alphacool Aurora Eiscontrol (item no. 15360)
Français Eisbecher 2 Aurora Glas Alphacool International GmbH Français avis général de sécurité Lisez les instructions de sécurité avant de commencer l‘installation. Matériel de Assemblée La tube montante de 140 mm est uniquement incluse dans le Eisbecher Aurora de 250 mm.
Alphacool International GmbH Eisbecher 2 Aurora Glas Français Assemblée Eisbecher 2 Aurora Glass Montage du support: Positions de la colonne montante: Retirez la pompe et les pieds, dévissez les vis marquées en rouge ici. Retirez avec précaution le couvercle avec la tringlerie, puis le tube de verre.
Français Eisbecher 2 Aurora Glas Alphacool International GmbH Assemblage de logements: Position d'incrustation: Veillez à ce que le filtre avec l'incrustation soit toujours placé en haut à gauche. Ce n'est que dans Utilisez les quatre vis M4x8 en conjonction avec les écrous M4. Selon le type de cette position que le débit d'eau est garanti.
Alphacool International GmbH Eisbecher 2 Aurora Glas Français Montage de radiateurs: Exemple de radiateur: 120-30 et 140-30 X-Flow. Dans cet exemple, les supports Utilisez les quatre vis M3x5 pour le montage du radiateur. Veuillez noter qu'en n'ont pas besoin d'être tournés.
Français Eisbecher 2 Aurora Glas Alphacool International GmbH Options de connexion: Fillport Fillport Nous ne recommandons que des liquides de refroidissement clairs issus de notre propre production (CKC, Tec Protect ou Eiswasser Crystal - pas d'UV" !) ou de Préparez le Eisbecher selon vos souhaits. Les exemples montrent quelques l'eau pure distillée ou filtrée par osmose pour le remplissage.
Alphacool International GmbH Eisbecher 2 Aurora Glas Français Connexion aRGB: Connexion Eisbecher 2 Aurora Plexi SATA Power Optionnel : Alphacool Aurora Eiscontrol (point n° 15360)
Page 22
Français Eisbecher 2 Aurora Glas Alphacool International GmbH Imprint: Alphacool International GmbH Marienberger Str. 1 38122 Braunschweig Support: +49 (0) 531 28874 – 0 Fax: +49 (0) 531 28874 – 22 E-Mail: info@alphacool.com General Managers: Andreas Rudnicki, Fabian Noelte WEEE-Reg.-Nr.: DE 54464644 Trade Register: Amtsgericht Braunschweig HRB 202390 VAT.ID.Nr.: DE270458421...