Programming Guide - Calpeda e-idos E-MXPM Instructions Pour L'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

suction hose, in order to avoid the hose narrowing due
to suction vacuum.
With the liquid level on the suction side above the
pump (inflow under positive suction head, par. 14. fig.
1) fit an inlet gate valve.
ATTENTION: the pump is equipped with a integrated
non-return valve into the pump suction, in order to
fill the suction pipe it is necessary to prepare a filling
system on the suction pipe (par. 14 fig. 4).
Follow local specifications if increasing network
pressure.
Install a strainer on the suction side of the pump to
prevent foreign particles from entering the pump.
6.4.3. Delivery pipe
Fit a gate valve in the delivery pipe to adjust delivery
and head.
With a geodetic head at outlet over 15 m fit a check
valve between the pump and the gate valve in order to
protect the pump from water hammering.
ATTENTION It is necessary to check that the restart
pressure (parameter UP02) is compatible with the
actual pressure of the pump and of the water column
of the system.
6.5. Electrical connection
OFF
Electrical connection must be carried out only
by a qualified electrician in accordance with
local regulations.
Follow all safety standards.
Make sure the frequency and mains voltage correspond
with the name plate data.
For use in swimming pools (not when persons are in
the pool), garden ponds and similar places, a residual
current device with IΔN not exceeding 30 mA must be
installed in the supply circuit.
Install a device for disconnection from the mains
(switch) with a contact separation of at least 3 mm in
all poles.
The pumps are supplied with incorporated capacitor
and thermal protector, with plug.
Connect the plug to a socket with an earth lead. The
motor will stop if overheating is detected. When the
windings cool down (after 2 to 4 minutes), the thermal
protector enables re-starting.
The pumps are supplied with power supply type
H07RN-F with plug and cable section equal to or greater
than the value defined in table 1 in paragraph 14.2.
When extension cables are used, make sure the cable
wires are of adequate size to avoid voltage drops.

7. PROGRAMMING GUIDE

7.1. Parameters
The following information is displayed:
- Parameters of pump status
- Programming parameters
- Alarms
7.2. Parameter of pump status
They allow to visualize:
- Initial screen (rUn, OFF, StB)
- the measure of the transducer
- the power absorption from the line
- the supply tension
- the operating temperature of the electronic board
- the current absorption
Starting from the basic display by pushing of the
directional arrow (plus) or (minus)
E-MXAM E-MXPM E-NGXM Rev4 - Operating Instructions
7.3. Programming parameters
To show the programming parameters, select
(menu).
Will be displayed progressively:
UP – User settings: these are the basis settings
that the user may change.
AP - Advanced settings: these settings are available
only to qualified personnel. To enter password is
required (see paragraph 7.6.).
GP – booster sets settings: to be set only if there is a
booster set group. To enter password is required (see
paragraph 7.6.).
Err - Last 5 alarms. In case of no error, it appears nOnE
AE - You can identify the firmware between the AE
menu. Firmware=AE01+AE02+AE03
7.4. Parameters
The
following
parameters
programmable:
7.4.1. UP – User settings
Par.
Description
UP01
Pump stop pressure. (bar).
UP02
Pump restart pressure (bar).
UP03
Operating mode
UP04
Select one of the two dry- run
modes available
7.4.2. AP – Advanced settings
Par.
Description
AP01
Pump suction pressure (bar)
AP02
Reset to factory set-up
AP03
Minimum run time of the pump 0 ÷ 15 s ECO
AP04
Stop delay time
7.4.3. GP – Booster sets settings
Par.
Description
GP01 Mode
GP02 Number of pumps
GP03 Booster set stop pressure
(bar)
GP04 Booster set restart
pressure (bar)
GP05 ID pumps
GP06 Threshold time
changeover
7.4.4. Booster set
GP02, GP03, GP04, GP05 and GP06 available only
if GP01=1. For proper operation GP02, GP03, GP04
and GP06 must be set equally for all pumps in the
booster set.
Procedure to activate the booster set mode.
1.
Operation to be done for each pump:
1.1 Turn on the pump and set it in STOP
1.2 Access the GP menu and enter the password
1.3 Set GP01=1
1.4 Set the number of pumps in the booster set
[GP02]
1.5 Set the stop pressure of the booster set [GP03]
are
available
and
Values
Standard
0 = Comfort
Comfort
1 = Eco
0,1
0
Values
Standard
0
nO, yES
nO
30
15 ÷ 30 s
COMFORT
0 ÷ 30 s
0
Values
Standard
0 = single pump
0
1 = booster set
rand = booster set with
random starts
2 ÷ 3
1 ÷ N
1 ÷ 24 h (+2min)
Page 13 / 72
EN

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

E-idos e-mxamE-idos e-ngxm

Table des Matières