ENGLISH
6.6 Starting up
The maximum service pressure in the installation is
equal to the zero-flow pressure of the pumps plus
ATTENTION !
any town water pressure at the booster inlet.
On the box, set the general disconnecting switch to "I" and the selec-
tor switches of the pumps to "Auto".
Automatic operation of the booster is then under the control of the
pressure switches and the timers.
Do not let the pump run with the discharge valve closed for more
than a few minutes.
7. MAINTENANCE
- The booster needs no particular maintenance in the course of
operation.
- The motor bearings are lubricated for life.
- The mechanical packing needs no maintenance in the course of
operation.
- In frosty weather and for prolonged stoppages of the pump, it must
be drained by unscrewing the bottom plug.
ATTENTION !
Fill the pump before using again.