GYSFLASH 51.12 CNT FV / 101.12 CNT / 103.12 CNT / 121.12 CNT FV /
123.12 CNT FV / 125.12 CNT FV / 101.24 CNT FV / 103.24 CNT FV /
TESTER MODE
General navigation :
1 Use the arrows to select the test to be performed
2 Press the START/STOP button to start the test
• Voltage test:
This mode allows you to view the voltage at the terminals of the charging clamps and thus use
your GYSFLASH as a voltmeter, in order to measure the battery voltage.
• Start-up test:
The purpose of this mode is to evaluate the state of a vehicle starting system (starter + battery) when the engine is turned on.
This test must be done with the battery connected to the vehicle.
1 Use the arrows to select the nominal voltage of the vehicle battery
2 Press the SELECT button to confirm
3 Connect the clamps to the vehicle battery
4 Start the engine by turning the ignition key
The charger automatically detects the engine start attempt and runs a calculation algorithm
5
to determine the state of the start system.
Test result: The charger indicates the minimum value of the battery voltage perceived during
the engine start phase, as well as the status of the start system in the form of a gauge.
• Alternator test :
This mode is used to determine the condition of the alternator in the vehicle. This test is performed on a vehicle with the engine
running.
1 Use the arrows to select the nominal voltage of the vehicle battery
2 Press the SELECT button to confirm
Test result: The charger indicates the voltage provided by the vehicle alternator, as well the
alternator status in the form of a gauge.
PROTECTIONS
This device is protected against short circuits and polarity reversals. It has an anti-spark system that prevents sparks when connec-
ting the charger to the battery. The device will not deliver current if there is no battery detected (no voltage in the clamps). This
charger is protected against handling errors by an internal fuse.
CONFIGURATION MENU
Navigation :
1 Press the MODE button for 3 seconds to access the Configuration Menu
20
20
25.48 CNT FV / 51.48 CNT FV / 53.48 CNT FV
EN
TESTER MODE
Voltage test
Voltage test
U=12.1V
Engine start test
12V
Engine start test
Umin=8.6V
Alternator test
12V
Alternator test
U=14.1V