Power Modes - GYS GYSFLASH 51.12 CNT FV Manuel D'utilisation

Masquer les pouces Voir aussi pour GYSFLASH 51.12 CNT FV:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
GYSFLASH 51.12 CNT FV / 101.12 CNT / 103.12 CNT / 121.12 CNT FV /
123.12 CNT FV / 125.12 CNT FV / 101.24 CNT FV / 103.24 CNT FV /
2 Confirm the restoration of the configuration.
3 The charger will then restore the penultimate configuration of the charger.
Export charging data on USB stick:
This function allows you to retrieve the charge history and data on a USB key, in order to be able to use them on a spreadsheet or
other.
1 Enter the "Export DATA" submenu
2 Confirm the recording of the charging data.
3 The charger will then copy the charging data to the USB stick as files, « .CSV »
Custom configuration
List of modes and profiles available for customization:
CHARGE MODE
Charge
Charge
type:
profiles
normal
AGM
water
Easy
Pb-CHARGE
boost
recovery+
Ca/Ca recov
LFP/LiFePO4
Li-ion std
Li-CHARGE
LFP cell+
Li-ion cell+
water
TRACTION
gel

POWER MODES

Showroom
DIAG+
25.48 CNT FV / 51.48 CNT FV / 53.48 CNT FV
Charging voltage
2.40 V/cell
Charging profile for lead batteries of the types Gel, MF, EFB, SLA...
Charging profile for most AGM lead-acid batteries including START and STOP.
2.45 V/cell
However, some AGM batteries require a lower voltage charge (Normal profile). Check the
battery manual if in doubt.
2.45 V/cell
Charging profile for open liquid-type lead-acid batteries with plug.
Charging profile dedicated to lead batteries that automatically adapts the charging current
according to the size of the battery.
2.40 V/cell
However, for maximum charge optimization, it is recommended, when possible, to use
normal, AGM or liquid charge curves.
Maximum current charge for lead-acid battery. This type of charge is ultra-fast.
2.42 V/cell
Warning : this type of charge must remain occasional in order to preserve bat-
tery life.
Charging profile for the recovery of severely damaged lead batteries. It is essential to
recover the battery outside the vehicle to avoid damaging the vehicle electronics and in a
2.40 - 2.50 V/cell
well ventilated area.
Caution: Recovery voltage up to 4.0 V/cell.
Charging profile for calcium battery recovery. The battery must be recovered outside the
2.45 - 2.66
vehicle to avoid damaging the vehicle's electronics and in a well-ventilated area.
V/cell
Caution: Recovery voltage can reach up to 2.75 V/cell.
3.60 V/cell
Charging profile for Lithium batteries type LFP (Lithium Ferro Phosphate)
Charging profile for standard lithium-ion batteries based on Manganese or Cobalt (NMC,
4.20 V/cell
LCO, LMO, MCO...)
Charging profile dedicated to LFP (Lithium Ferro Phosphate) type lithium-ion cells with
3.60 V/cell
selection of the number of cells in series to be charged.
Charging profile dedicated to standard lithium-ion cells based on Manganese or Cobalt
4.20 V/cell
(NMC, LCO, LMO, MCO...) with selection of the number of cells in series to be charged.
2.42 V/cell
Charging profile dedicated to open lead traction batteries for forklift trucks.
2.35 V/cell
Charging profile dedicated to gel-type traction batteries for forklift trucks.
Maintains the battery's state of charge and supplies power when using the electrical consumers of a demonstra-
tion vehicle.
Supplies energy requirements during the vehicle diagnostic work.
EN
Continue?
YES
Loading
Export DATA
Continue?
Yes
Loading