GYS GYSFLASH 51.12 CNT FV Manuel D'utilisation page 25

Masquer les pouces Voir aussi pour GYSFLASH 51.12 CNT FV:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
GYSFLASH 51.12 CNT FV / 101.12 CNT / 103.12 CNT / 121.12 CNT FV /
123.12 CNT FV / 125.12 CNT FV / 101.24 CNT FV / 103.24 CNT FV /
10
Err11: Time_Out
11
Err12: Q>___Ah
12
Err13: U<__V
13
Err14: Bat_UVP
14
Err15: U<__V
15
Err16: Bat_NOK
16
Err17: Recov_NOK
17
Err18: U>0V
18
Err19: Cable_NOK
19
Err20: U<__V
20
Err21: U<__V or Err22: U<__V
21
?
22
?
23
24
Err27: Cable_NOK
25
Err28: COM_NOK
WARRANTY
The warranty covers faulty workmanship for 2 years from the date of purchase (parts and labour).
The warranty does not cover:
• Transit damage.
• Normal wear of parts (eg. : cables, clamps, etc..).
• Damages due to misuse (power supply error, dropping of equipment, disassembling).
• Environment related failures (pollution, rust, dust).
In case of failure, return the unit to your distributor together with:
- The proof of purchase (receipt etc ...)
- A description of the fault reported
25.48 CNT FV / 51.48 CNT FV / 53.48 CNT FV
Triggering the time limit
Abnormally long charge
Tripping the overcharge protection
Abnormally low battery voltage when
checking the charge
Abnormally low battery voltage during
UVP Wake up
Battery too low
Battery out of order
Battery recovery failure
Presence of a voltage at the clamp
terminals when calibrating the cables
Cable calibration failure
Triggering of the abnormal undervol-
tage protection
Abnormally low battery voltage during
charging
Key not detected
No configuration file (.gfc) is present
on the key
Corrupted file
Multi-charger mode :
Parallel charging cables fail
Multi-charger mode :
Communication failure between
chargers
Presence of a consumer on the battery disrupting the charge
Battery to be replaced
Presence of a consumer on the battery disrupting the charge
Battery to be replaced
Battery to be replaced
Presence of a short circuit, check the assembly
Battery to be replaced
Check that the selected mode is compatible with the battery
voltage (e. g. : 24 V battery in 12 V mode)
Battery to be replaced
Battery to be replaced
Battery to be replaced
Check the assembly
Charging cables to be replaced
Incorrect connection, check the assembly
Presence of a short circuit, check the assembly
Battery to be replaced
Presence of a consumer on the battery
Check that the USB key is correctly connected to the charger.
Check that your files are present at the root of the USB key. Do
not put them in a folder or sub-folder.
The file you wish to download is corrupted. Delete and reinstall
the file on the key.
Load cables to be replaced.
Poor connection, check assembly (PHM).
To switch back to single charger operation, select OFF for the
Multi-Charger function.
No communication, check SHM mounting and SLAVE X charger
configuration.
To switch back to single charger operation, select OFF for the
Multi-Charger function.
EN