Measurements
8.0 Clear/Display saved Measurement Values
It is possible to delete individual data or all data by
means of the "Clear" key (25). Furthermore, it is pos-
sible to display the total amount of all measurement
values on the screen.:
8.1 Display of the Total Amount of
Measurement Values:
Set measurement function selection dial
(19) to one of the 7 measurement functions.
Briefly press the "Clear" key (25). An acoustic
signal is audible.
The number of all saved measurement val-
ues is briefly displayed.
8.2 Delete the Last Value Saved:
Set measurement function selection dial
(19) to one of the 7 measurement function.
Briefly press the "Clear" key (25).
An acoustic signal is audible and the amount
of measurement values saved is displayed.
Press again briefly the "Clear" key (25) until
the number of saved measurement values
displayed is reduced by 1 and a further
acoustic signal is audible.
Now release the Clear key (25) to prevent the
total memory from being cleared.
Clearing of the last value saved can be repeat-
ed as often as desired as long as data is still
contained within the memory.
34
02.10.2008
15:37 Uhr
8.3 Clearing all Measurement Values Saved:
Set measurement function selection dial
(19) to one of the 7 measurement functions.
Press the "Clear" key (25) for approx. 5 sec-
onds
An acoustic signal is audible. The number of
all measurement data saved is displayed.
The number of the measurement values is
reduced by 1.
After approx. 2 s the last measurement value
saved is deleted and an acoustic signal is au-
dible.
After further 2 seconds another acoustic sig-
nal is audible and all data is cleared. "0" is
briefly displayed in the small result window.
The memory is now completely cleared. The
symbol "M" disappears from the display.

9.0 LCD Backlight

The key (27) is used to switch the backlight on or
off. After approx. 20s following the last key press-
ing or the last measurement function selection dial
operation, the backlight is automatically switched
off to reduce battery consumption.