TROUBLESHOOTING
Problem
Compressor will not start.
Low pressure.
Safety valve releasing.
Pressure switch will not turn
off Compressor.
®
Possible Cause
1. Blown fuse or circuit
breaker tripped.
2. Loose electrical connec
tions.
1. Defective check valve.
2. Air leak in safety valve.
3. Defective Valve Plate.
4. Drain Valve not fully
closed.
1. Defective pressure switch.
2. Defective Safety Valve.
Defective pressure switch.
7
Possible Solution
1. Replace fuse.
-
2. Make sure Compressor is
plugged into a working, 120
volt, grounded, electrical
outlet.
1. Have a qualified service
technician replace check
valve.
2. Check valve by pulling on
ring. If condition persists,
have a qualified service
technician replace valve.
3. Replace Valve Plate.
4. Close Drain Valve.
1. Have a qualified service
technician replace pressure
switch.
2. Replace Safety Valve.
Immediately unplug Com
pressor from its electrical
outlet. Do not operate
Compressor until a qualified
service technician can
replace pressure switch.
25F538