To customize settings "deceleration", "end of position speed", "opening speed" and "delay", proceed
like this:
Deceleration:
1. Turn OFF the switch 2.
2. Press briefly one time on the push button (-) in order to start.
The LED flashes the number of times according to the value saved.
3. Press on push button (+) or push button (-) to increase or decrease parameter value.
The LED flashes the number of times according to the value saved.
4. Press on push button BP prog. to approve the new parameter value.
Recommended settings for a max opening speed:
• 8 for a door of 80kg
• 5 for a door of 40kg
• 2 for a door of 10kg
End of position speed:
1. Turn OFF the switch 2.
2. Press briefly one time on the push button (+) in order to start.
The LED flashes the number of times according to the value saved.
3. Press on push button (+) or push button (-) to increase or decrease parameter value.
The LED flashes the number of times according to the value changed.
4. Press on push button BP prog. to approve the new parameter value.
Opening speed:
1. Turn ON the switch 2.
2. Press briefly one time on the push button (+) in order to start.
The LED flashes the number of times according to the value saved.
3. Press on push button (+) or push button (-) to increase or decrease parameter value.
The LED flashes the number of times according to the value changed.
4. Press on push button BP prog. to approve the new parameter value.
Delay:
1. Turn ON the switch 2.
2. Press briefly one time on the push button (-) in order to start.
The LED flashes the number of times according to the value saved.
3. Press on push button (+) or push button (-) to increase or decrease parameter value.
The LED flashes the number of times according to the value changed.
4. Press on push button BP prog. to approve the new parameter value.
Return to factory:
1. Press and hold down the setup button for roughly 5 seconds.
The LED comes on.
2. Press and hold down the setup button for roughly 5 seconds.
The LED goes out then flashes quickly: all settings are reset to default values.
25