Installation to Triple Wood Stud Wall
• Installer must verify that the supporting surface will safely support the combined load of the equipment and all attached
hardware and components.
• Tighten wood screws so that wall plate is firmly attached, but do not overtighten. Overtightening can damage the
screws, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
• Make sure that mounting screws are anchored into the center of the stud. The use of an "edge to edge" stud finder is
highly recommended.
• Hardware provided is for attachment of mount through standard thickness drywall or plaster into wood studs. Installers
are responsible to provide hardware for other types of mounting situations.
1
Wall plate (AA) can be mounted to three studs that are 16" apart. Use a stud finder to locate the edges of the
studs. Use of an edge-to-edge stud finder is highly recommended. Based on their edges, draw a vertical line down
each stud's center. Place wall plate on wall as a template. The top mounting slots should be located above the
desired screen center as indicated by dimension X in figure 1.3 and chart below. Level plate, and mark the center
of the six mounting holes. Make sure that the mounting holes are on the stud centerlines. Drill six 5/32" (4 mm) dia.
holes 2-1/2" (64 mm) deep. Make sure that the wall plate is level, secure it using six #14 x 2.5" wood screws (CC)
as shown in figure 1.4.
Skip to step 2.
STUD
AA
CS = center of screen
Model #
SF670, SF670-S, SF670P,
SF670P-S
SF680, SF680-S, SF680P,
SF680P-S
WARNING
6"
6"
(152 mm)
(152 mm)
CS
X2
X
CS
fig. 1.3
X Dimension
n/a
3-3/4" (95 mm)
AA
CC
X2 Dimension
3/4" (19 mm)
n/a
4 of 24
ISSUED: 11-09-07 SHEET #: 202-9253-2 10-13-08