Function F5 - Activate continuous operation, see fold-out page IV, Fig. [22].
Button Description
Start the function menu
- Select the function by simultaneously pressing and holding the - / + buttons.
- F5 Function select by turning the ring
• Start F5 - Activate continuous operation
=> Confirm by simultaneously pressing the - / + buttons.
- Press Start/Stop button of digital controller.
- Press - button of digital controller.
- Press + button of digital controller.
=>
Pressing the - / + buttons simultaneously starts the continuous operation.
False entry => abort menu.
Caution: Risk of scalding. The 42 °C setted safety stop is deactivated.
Abort of the function after 15 minutes (after that cold water runs for a minute) or
prematurely by operating the digital controller as well as a the transceiver (no cold
water running).
Maintenance
Inspect and clean all components and replace if necessary.
Disconnect voltage supply.
Disconnect all plug-in connectors.
Shut off hot and cold water supply.
I. Change digital controller batteries, see fold-out page IV, Fig. [24] and
fold-out page III, Figs. [9] to [13].
Insert batteries with correct polarity.
II. Change functional unit battery, see fold-out page IV, Figs. [25]
and [26].
The battery must be replaced 10 years after commissioning the functional
unit, at the latest. Insert battery with correct polarity.
Assemble in reverse order. Approx. 10 seconds after the voltage supply is
established there are two brief water pulses and the buttons of the digital
controller are now inoperative for 60 seconds.
III. Remove and clean mousseur (13 220) , see fold-out-page IV,
Fig. [27]. Assembly in reverse order.
Fault
Cause
Water does not flow
• Water supply interrupted
• Plug-in connector without contact or no voltage
supply
Flow rate too low
• Fitting mousseur dirty or defective
• Functional unit not adapted to local conditions
Water too cold/hot
• Functional unit not adapted to local conditions
No function
• No voltage supply to functional unit
• Digital controller not ready or registered
• Digital controller out of range
Segment flashes 1x white
• Radio interference
• Obstacle in transmission path
• 1x: Batteries digital controller almost empty
• 2x and water pulses: Battery functional unit
Segment flashes green
almost empty
• 2x without water pulses: Battery functional
unit not connected or empty
• 3x: Temperature too high
• Software malfunction
Segment flashes 1x yellow
• Hard- or software malfunction
Segment flashes 1x red
Please pass these instructions on to the end user of the fitting.
7
The right to make technical modifications is reserved.
Visualization
Illuminated ring flashes red 1x.
Illuminated ring flashes red 5x.
Illuminated ring flashes green 1x.
Segment of illuminated ring flashes blue 1x.
Segment of illuminated ring flashes blue 1x.
Segment of illuminated ring flashes blue 1x.
Illuminated ring flashes cyan 3x.
Illuminated ring flashes violet 3x.
Illuminated ring flashes cyan 3x.
Service
In the event of problems with installation, please switch off the voltage
supply and consult a specialist installer or the GROHE Service Hotline via
email at TechnicalSupport-HQ@grohe.com.
Replacement parts
See fold-out page I (* = special accessories).
Disposal instructions
This category of device does not belong in the domestic waste,
but must be disposed of separately in accordance with the
relevant local national regulations.
Dispose of batteries in accordance with national regulations.
Remedy
- Open shut-off valves, isolating valves
- Attach plug-in connectors and connect voltage supply
- Replace mousseur, see section Maintenance
- Adapt functional unit to local conditions, see Function F2 - Setting
mode
- Adapt functional unit to local conditions, see Function F2 - Setting
mode
- Connect voltage supply via voltage supply unit
- Register digital controller, see Function F3 - Register/de-register
- Reduce distance or use special accessory transceiver
(order no 36 356)
- Deactivate potential source of interference and check function again
=> If positive reconfigure the interference source (eg wireless router)
- Rectify the fault see section Operating conditions
- Check installation or replace unit battery, see section Maintenance
- Check installation or replace unit battery, see section Maintenance
- Connect plug in-connector battery or replace battery, see section
Maintenance
- Wait until feeler gauge is cooling down
- Calibrate functional unit, see section F2 - Setting mode
- Switch off the voltage supply and consult a specialist installer
or the GROHE Service Hotline
- Switch off the voltage supply and consult a specialist installer
or return the product to GROHE