Different functions (F1 to F5) can be set or activated via the digital controller.
Start of the function menu only when no water is flowing.
Function F1 - Automatic filling, see fold-out page IV, Fig. [22].
Button Description
Start the function menu
- Select the function by simultaneously pressing and holding the - / + buttons.
• Start function F1 - Automatic filling
=> Confirm by simultaneously pressing the - / + buttons.
- Stop the water flow/timer by turning the ring anti-clockwise.
- Continue the water flow/timer by turning the ring clockwise.
- Again stop the water flow/timer by turning the ring anti-clockwise.
- After 30 minutes (max. running time) the water flow stops automatically.
- Pressing the - / + buttons saves the quantity/duration and exits the menu. Abort after
3 minutes without triggering (only when no water is flowing).
Abort the function menu by pressing and holding Start/Stopp.
Function F2 - Setting mode (adaption to the local conditions), see f old-out page IV, Figs. [22] and [23].
Button Description
Start the function menu
- Select the function by simultaneously pressing and holding the - / + buttons.
- F2 Function select by turning the ring
• Start F2 - Setting mode
=> Confirm by simultaneously pressing the - / + buttons.
Risk of scalding, the outlet temperature could exceed 42 °C!
- Turn ring and set minmum flow rate.
=>
Confirm the setting by simultaneously pressing the - / + buttons.
- Turn ring and set maximum flow rate.
=>
Confirm the setting by simultaneously pressing the - / + buttons.
- Turn ring, measure water outlet temperature and set at 23 °C.
=>
Confirm the setting 23 °C by simultaneously pressing the - / + buttons.
- Turn ring, measure water outlet temperature and set at 42 °C.
Confirm the setting 42 °C by simultaneously pressing the - / + buttons.
=>
Abort the function menu by pressing and holding Start/Stopp button or after
3 minutes without triggering.
Function F3 - Register/de-register additional digital controller (maximal 3 Controller), see f old-out page IV, Fig. [22].
Button Description
Start the function menu
- Select the function by simultaneously pressing and holding the - / + buttons.
- F3 Function select by turning the ring
• Start F3 - Register additional digital controller
=> Confirm by simultaneously pressing the - / + buttons.
- Press the buttons 1 + 3 of the additional digital controller simultaneously in order to
register it.
- Pressing the - / + buttons simultaneously on the pending digital controller saves the
selection and exits the menu.
• Start F3 - De-register additional digital controller
=> Confirm by simultaneously pressing the - / + buttons.
- Pressing the - / + buttons simultaneously on the factory digital controller to de-
register all additional controllers.
Abort the function menu by pressing and holding Start/Stopp button or after
3 minutes without triggering.
Function F4 - Factory reset, see f old-out page IV, Fig. [22].
Button Description
Start the function menu
- Select the function by simultaneously pressing and holding the - / + buttons.
- F4 Function select by turning the ring
• Start F4 - Factory reset
=> Confirm by simultaneously pressing the - / + buttons.
- Press + button of digital controller.
- Press - button of digital controller.
- Press Start/Stop button of digital controller.
=> Confirm by simultaneously pressing the - / + buttons.
False entry => abort menu.
Abort the function menu by pressing and holding Start/Stopp button or after
3 minutes without triggering.
Please pass these instructions on to the end user of the fitting.
The right to make technical modifications is reserved.
Visualization
Illuminated ring flashes red 1x.
Illuminated ring flashes green 1x and timer starts.
Water flow/timer stops.
Water flow/timer continues.
Water flow/timer stops.
Water flow stops.
Illuminated ring flashes green 3x.
Illuminated ring flashes violet 1x.
Visualization
Illuminated ring flashes 1x red.
Illuminated ring flashes 2x red.
Illuminated ring flashes green 1x and water flow starts.
Illuminated ring flashes green 1x.
Illuminated ring flashes green 1x.
Illuminated ring flashes green 1x.
Illuminated ring flashes green 3x.
Illuminated ring flashes violet 1x.
Visualization
Illuminated ring flashes red 1x.
Illuminated ring flashes red 3x.
Illuminated ring flashes green 1x.
Illuminated ring flashes green 1x.
Illuminated ring flashes green 3x.
Illuminated ring flashes green 1x.
Illuminated ring flashes green 3x.
Illuminated ring flashes violet 1x.
Visualization
Illuminated ring flashes red 1x.
Illuminated ring flashes red 4x.
Illuminated ring flashes green 1x.
Segment of illuminated ring flashes blue 1x.
Segment of illuminated ring flashes blue 1x.
Segment of illuminated ring flashes blue 1x.
Illuminated ring flashes green 3x.
Illuminated ring flashes violet 3x.
Illuminated ring flashes violet 1x.
6