Electrical test data
• Software class:
• Contamination class:
• Rated surge voltage:
• Temperature for ball impact test:
The test for electromagnetic compatibility (interference emission test) was
performed at the rated voltage and rated current.
Approval and conformity
This product conforms to the requirements of the relevant EU
directives.
The conformity declarations can be obtained from the following address:
GROHE Deutschland Vertriebs GmbH
Zur Porta 9
D-32457 Porta Westfalica
Electrical installation
Electrical installation work must only be performed by a
qualified electrician. This work must be carried out in
accordance with the regulations to IEC 60364-7-701
(corresponding to VDE 0100 Part 701) as well as all national
and local regulations.
Rough installation
• The functional unit must be accessible for maintenance work.
• The plug-in connectors must be accessible.
• The functional unit must not be installed with the lid facing downwards.
• A vacant tube must be used to connect the functional unit to the voltage
supply unit.
Prepare the wall for the installation, refer to the dimensional drawing on
fold-out page I and Fig. [1] on fold-out page II.
- Prepare holes for the functional unit as well as slots for the pipes and
empty conduit.
Operation of the digital controller, see fold-out page IV, Fig. [22].
Button Description
Start/Stop button
Starts and stops the water flow at the saved water temperature and flow rate.
Pause button
Interrupts the water flow. Pressing the button again within 30 seconds, the operation
continues with the last selected settings.
The temperatures is limited to the value of the safety stop.
Temperature buttons
Starts the water flow and decreses or increases the water temperature.
Display when minimum temperature is reached (-).
Display when safety stop is reached (+).
Display after overriding the safety stop (+).
42 °C
Overriding the safety stop
When the safety stop is reached (factory setting 42 °C), press and hold button - / +
simultaneously. Then press button + several times.
Volume control
Turning clockwise starts the functional unit and increases the flow rate until maximum.
Turning anti-clockwise reduces the flow rate until minimum.
Memory function
When the water is running the current settings can be saved by pressing and holding
the button.
Temperatures above 42 °C are not saved.
Cleaning service mode
If no water is flowing, pressing and holding both buttons simultaneously activates
cleaning service mode.
In the cleaning service mode all outlets closed and without function for 2 minutes .
Abort the cleaning service mode within two minutes by simultaneously pressing and
holding both buttons.
Please pass these instructions on to the end user of the fitting.
5
The right to make technical modifications is reserved.
Flush pipes thoroughly before and after installation (observe EN 806).
B
Install functional unit, see fold-out page II, Figs. [2] to [4].
2
- Route mixed water outlet to the fitting, see Fig. [3].
2500 V
100 °C
Do not solder the connections.
Rough installation
Install spout, see fold-out page II, Figs. [5] to [7].
Install pop-up waste, see fold-out page III, Fig. [8]. Seal plug-hole rim!
Insert batteries into digital controller, see Figs. [9] to [13].
Grease seals. Insert batteries with correct polarity.
The digital controller is registered with the functional unit in the factory.
Secure digital controller, see Fig. [14a] or [14b] to [17].
Connect functional unit, see fold-out page IV, Figs. [18] and [19].
Open the hot and cold water supply and check that the connections
are watertight. Water flows until the voltage supply is established.
Connect battery housing to functional unit, see Fig. [20].
Establish voltage supply via plug-in voltage supply, see Fig. [21].
Approx. 10 seconds after the voltage supply is established there are two
brief water pulses and the buttons of the digital controller are now
inoperative for 60 seconds.
The reception can be improved using the transceiver special accessory
(Prod. no. 36 356).
The functional unit must be adapted to the local conditions, see section
Function menu of the digital controller, F2 - Setting mode.
Settings in the event of a power failure/when changing batteries
No settings saved by the user will be lost when changing the batteries or
in the event of an interruption of the voltage supply to the functional unit.
Visualization
The temperature is represented by the illuminated ring.
[from blue to orange (safety stop) to red].
The temperature is represented by the illuminated ring
Illuminated ring flashes blue 3x.
Illuminated ring flashes orange 3x.
Illuminated ring changes from orange to red.
Illuminated ring flashes 3x orange when the safety stop
is reached/unlocked.
Water flow is interrupted briefly and illuminated ring
flashes green 3x.
Illuminated ring flashes violet 3x.
Illuminated ring flashes violet 1x when actuated.
Illuminated ring flashes violet 3x.