EN
DESCRIPTION
Compressed air powered reciprocating piston pump. This high flow
capacity pump is compatible with mineral and synthetic oils and suitable
for large installations with long length piping supplying several fluid
outlets simultaneously.
WARNINGS
WARNING! Read all instruction manuals, tags, and labels before
!
operating the equipment. This equipment is for professional use only.
• The use of non compatible fluids may cause damage in the pump and
serious personal injury. This equipment is not intended for use with
fluids that fall within the Group 1 fluid as defined that are explosive,
extremely flammable, highly flammable, flammable, very toxic, toxic,
oxidizing or where the vapor pressure if greater than 0,5 bar (7 psi)
above the pressure atmospheric at the maximum allowable temperature.
• The pump generates high or very high pressures. Do not exceed the
maximum air inlet pressure of 12 bar (170 psi).
• A direct hit against the human body may result in an injury.
INSTALLATION
These pumps can be installed directly on a drum or tank. However, we
recommend installation with a wall-mounting bracket (360132).
They can be installed in three different ways:
a. Wall mounting (using wall bracket 360132). Mount the wall bracket
to the wall securely. Insert the pump through the wall bracket and
attach it with screws (fig. 1).
b. Direct drum or tank mounting. Screw the proper suction tube (see fig. 2)
to the foot valve of the pump. Insert the tube through the drum/
tank cover. Secure the pump to the cover with M10 screws (4 holes
@ 112 mm center hole pattern diameter).
c. Adjustable drum or tank mounting, using bung adapter 360006.
Screw the proper suction tube (see fig. 3) to the foot valve of the
pump. Screw the nut of the bung adapter to the 2" opening of the
cover. Insert the suction tube through the nut and secure it with the
star nut at the desired height.
These pumps are intended to be installed directly on 200 liters drums,
by fixing them to the drum cover using four M10 screws.
2
853 801 R. 06/20
SAMOA Industrial, S.A. · Pol. Ind. Porceyo, I-14 · Camino del Fontán, 831 · 33392 - Gijón - Spain · Tel.: +34 985 381 488 · www.samoaindustrial.com
Fig. 2
SUCTION TUBE
PUMP
536030
536031
This pump can be mounted on the wall, with wall mounting bracket
(Part. No. 360132), or directly on a drum or tank, using a suction tube
of a suitable length.
• This unit may have stored pressure, release all pressure and disconnect
from any fluid systems before servicing. To ensure safe operation of this
unit, all service work should be by qualified personnel only.
• When not in use, be sure to shut off the air supply to avoid accidents.
• Do not alter or modify this equipment. Use only Samoa Industrial, S.A.
genuine components. Any unauthorized tampering with this
equipment, improper use, poor maintenance or removal of
identifications labels may invalidate the guarantee.
• All fittings in the system connected to the outlet of the pump should be
suitable for the maximum possible pressure generated by the pump/air
motor. If the systems cannot be designed to take the maximum pressure
produced by the pump, safety valves or diverter valves should be fitted.
DRUM
TANK
539012
368112
539011
539041
360132
Fig. 1
Fig. 3