INSTALLATION LAYOUT
4
2
COMPONENTS
Motor
1
Control unit
2
3
Transmitter
Receiving module
4
5
Photocells
Flashing light
6
LENGTH OF THE CABLE
Power supply (230V)
24V motor power supply
24V motor power supply
Photocells (TX)
Photocells (RX)
Key switch
Safety edges
Flashing light
Antenna (integrated into the flashing light)
6
1
C
ADDITIONAL ACCESSORIES
Key switch
A
Pillar photocells
B
C
Safety edges
< 10 metres
3G x 1,5 mm
2
2G x 1,5 mm
2
2G x 1,5 mm
2
2 x 0,5 mm
2
4 x 0,5 mm
2
2 x 0,5 mm
2
2 x 0,5 mm
2
2 x 1,5 mm
2
RG174
5
1
3
from 10 to 20 metres
3G x 1,5 mm
2
2G x 1,5 mm
2
2G x 1,5 mm
2
2 x 0,5 mm
2
4 x 0,5 mm
2
2 x 0,5 mm
2
2 x 0,5 mm
2
2 x 1,5 mm
2
RG174
A
B
from 20 to 30 metres
3G x 2,5 mm
2
2G x 2,5 mm
2
2G x 2,5 mm
2
2 x 0,5 mm
2
4 x 0,5 mm
2
2 x 0,5 mm
2
2 x 0,5 mm
2
2 x 1,5 mm
2
RG174
15