CONNECTING THE SUCTION HOSE TO THE PUMP
1. Slide the suction hose camlock onto the pump inlet camlock.
2. Secure the camlock by squeezing the two levers tight towards the hose.
CONNECTING THE FIRE HOSE
1. Interlock the claws of the fire hose coupling on the hose and pump outlet.
2. Rotate the fire hose coupling clockwise to tighten.
3. Slide the hose clamp over the end of the discharge hose. Slide the discharge hose onto the hose barb.
Tighten the hose clamp securely.
CONNECTING FIRE NOZZLE
1 Interlock the claws of the fire hose coupling on the fire hose and fire nozzle.
2. Rotate the fire nozzle coupling clockwise to tighten.
6
All manuals and user guides at all-guides.com
2 in. High Pressure Transfer Pump
Fig. 2
Fig. 3
8408890
For technical questions call 1-800-665-8685