Important Hints; Symbols; Unpacking; Use Of Tilt Handle - Hameg Instruments HM5510 Manuel

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

I m p o r t a n t h i n t s

Important hints

Symbols

(1)
(2)
(3)
Symbol 1:
Attention, please consult manual
Symbol 2:
Danger! High voltage!
Symbol 3:
Ground connection
Symbol 4:
Important note
Symbol 5:
Hints for application
Symbol 6:
Stop! Possible instrument damage!

Unpacking

Please check for completeness of parts while unpacking. Also
check for any mechanical damage or loose parts. In case of
transport damage inform the supplier immediately and do not
operate the instrument.
Check setting of line voltage selector whether it corresponds
to the actual line voltage.

Use of tilt handle

To view the screen from the best angle, there are three dif-
ferent positions (C, D, E) for setting up the instrument. If the
instrument is set down on the fl oor after being carried, the
handle automatically remains in the upright carrying position
(A). In order to place the instrument onto a horizontal surface,
the handle should be turned to the upper side of the instrument
(C). For the D position (10° inclination), the handle should be
turned to the opposite direction of the carrying position until
it locks in place automatically underneath the instrument. For
the E position (20° inclination), the handle should be pulled to
release it from the D position and swing backwards until it
locks once more. The handle may also be set to a position for
horizontal carrying by turning it to the upper side to lock in the
B position. At the same time, the instrument must be lifted,
because otherwise the handle will jump back.

Transport

Please keep the carton in case the instrument may require
later shipment for repair. Improper packaging may void the
warranty!
26
Subject to change without notice
STOP
STOP
HINT
(4)
(5)
(6)
STOP

Storage

Dry indoors storage is required. After exposure to extreme
temperatures 2 h should be allowed before the instrument
is turned on.

Safety guidelines

This instrument was manufactured and tested in accordance
with VDE 0411, part 1, „Safety Rules for Electric Measuring and
Control Laboratory Instruments", it left the factory in proper
safe condition. It conforms hence also with the European
standard EN 61010-1 resp. the international standard IEC
61010-1. In order to keep this condition up and to guarantee safe
operation the user is requested to observe the warning hints
as well as the other hints carefully which are contained in this
manual. Housing, chassis, and all measuring connections are
connected to the mains safety earth. The instrument conforms
to the rules for Protective Class I. All metal parts which can be
touched were tested against the mains with 2200 V DC.
Safety rules require that this instrument may only be operated
from a mains outlet which conforms to the respective safety
standards. The mains plug must be inserted fi rst before any
signals may be connected to the instrument.
In case there are doubts about the conformity of a mains
outlet the outlet must be tested according to DIN VDE 0100,
part 610.
It is prohibited to disconnect the safety earth eit-
her within the instrument or externally!
Before operation check whether the mains voltage cor-
responds to the mains voltage selector setting of the
instrument.
This instrument may only be opened by qualifi ed person-
nel.
Prior to opening the instrumjent must be disconnected
from the mains and all other signals.
In any of the following cases do not use the instrument any
more and store it in a secure place:
Visible damage
Damaged mains cord
Damaged fuse holder
Loose parts inside the instrument
Does not function any more.
After prolonged storage under unfavourable conditions
such as humidity, or in the open.
Excessive abuse during transport.
Most electron tubes generate gamma rays. With
this instrument the ion dose remains far below the
allowed limit of 36 pA/kg.
This measuring instrument must only be used
STOP
by personnel familiar with the risks and dangers
associated with the measurement of electrical
signals.
STOP
This instrument may only be operated from a
mains outlet conforming to the applicable safety
standards. It is prohibited to disconnect the safety
earth. The mains plug must be inserted prior to
connecting any signals to the instrument.
STOP

Publicité

Table des Matières
loading

Table des Matières