Troubleshooting
If the appliance does not function properly, please
check the below table for the solution. If you are
still unable to solve the problem, please contact the
supplier/service provider.
Problems
The appliance does not switch
ON.
Cooling fan is operating even after
the appliance is switched to OFF
mode.
Technical specification
Item no.
Operating voltage and frequency
Rated input power
Temperature setting
Timer setting
Protection class
EN
Waterproof protection class
Oil tank
Dimension
Remark: Technical specification is subjected to change without prior notification.
Warranty
Any defect affecting the functionality of the ap-
pliance which becomes apparent within one year
after purchase will be repaired by free repair or re-
placement provided the appliance has been used
and maintained in accordance with the instructions
and has not been abused or misused in any way.
Your statutory rights are not affected. If the appli-
ance is claimed under warranty, state where and
8
• Error codes shown on the digital display (6). (See
Possible cause
- Power plug is not connected properly
with the electrical outlet.
- On/OFF (1) button is not pressed.
- This is normal. The cooling fan contin-
ues running in OFF mode for some time
to cool down all internal elements.
215012 (Single tank version)
3500W
60°C ~ 190°C (with 5 °C interval)
0 min ~ 15 mins (with 30 seconds interval)
8L
290 x 485 x (H) 406 mm
when it was purchased and include proof of pur-
chase (e.g. receipt).
In line with our policy of continuous product devel-
opment we reserve the right to change the product,
packaging and documentation specifications with-
out notice.
--> Error codes display)
Possible solution
- Check the power plug to make sure
it is connected properly.
- Press the On/OFF (1) button to start
operation.
- Wait until the cooling fan stops ro-
tating.
215029 (Double tanks version)
220-240V~ 50-60Hz
Class I
IPX4
580 x 485 x (H) 406 mm
2 x 3500W