Hendi 215012 Mode D'emploi page 6

Masquer les pouces Voir aussi pour 215012:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 33
Switch ON
• Make sure the tap is closed and that the oil tank
has enough oil, level should be between MIN and
MAX marking.
• Connect the power plug to a suitable electrical
supply outlet.
Operation
• Press ON / OFF (1) to switch ON the appliance.
FILL OIL (5) indicator flashes and buzzer sound
will be heard to alert the user to fill up the oil
tank container.
• Then, please make sure again the oil level is be-
tween the MIN and MAX marking.
• If the oil tank contains enough oil, press FILL OIL
(5) to cancel the buzzer sound and the indicator
light. The display will show the default tempera-
ture of 140°C.
• After that, press UP (3) or DOWN (4) button to
increase or decrease the temperature. (Range:
60°C ~ 190°C, with 5°C interval).
Setting Timer
• Timer can be set by pressing the TIMER (2) to
EN
enter TIMER mode.
• Then, press UP (3) or DOWN (4) to increase or
decrease the time. (Range: 0 min ~ 15 mins, with
30 seconds interval). Default setting is 0 min.
• When the timer is set, it will be stored automati-
cally within 5 seconds. Then, timer will be started
to count down from the set time.
• Display (6) will alternate between Time remaining
/ Set temperature.
• When the set time has elapsed, a beeping sound
(long and short) will be heard and "End" will be
shown in the display (6). The appliance will keep
on heating if the set temperature isn't reached.
• Press and hold the UP (3) or DOWN (4) for fast
adjustment of timer.
6
• Next, press the power switch at the rear side of
the appliance to connect the power supply. Green
indicator on the power switch will light up.
• Now the appliance is connected to electrical sup-
ply.
• When the oil doesn't reach the set temperature,
"HEATING Indicator" will light up and "KEEP
WARM Indicator" will go out.
• When the oil temperature reaches the set tem-
perature, "HEATING Indicator" will go out and the
"KEEP WARN Indicator" will light up.
Note: During operation, if no temperature is set,
the appliance will maintain to the default temper-
ature 140°C.
Note: 1. Press and hold the increase setting button
(3) or decrease setting button (4) for fast
adjustment.
2. Every time, you press any button on the
panel, a short beep sound will be heard to
alert the user.
3. After an extended period of operation, it is
normal for the cooling fan inside to con-
tinue running in OFF mode for some time.
Before unplug the appliance, wait until the
cooling fan stops running.
4. The appliance's outer surface is still hot
even after switch to OFF mode. Please
wait the appliance completely cool down
before touching or cleaning.
5. If no any button on the control panel is
pressed during operation for 4 hours, the
appliance will then switch to OFF mode
automatically.