ASSEMBLY INSTRUCTIONS
The propane cylinder must be constructed and marked in accordance with the U.S. Department of
Transportation (DOT) Specifications for LP-Gas Cylinders, or the Standard for Cylinders, Spheres
and Tubes for Transportation of Dangerous Goods and Commission, CAN/CSA-B339, as applicable.
The cylinder must have a listed overfilling prevention device.
The cylinder must have a connection device compatible with the connection for the appliance.
Never connect an unregulated propane cylinder to this appliance.
The cylinder must include a collar to protect the cylinder valve. The gas cylinder should not be
dropped or handled roughly.
The LP-gas supply cylinder must be disconnected when this appliance is not in use. Storage of
an appliance indoors is permissible ONLY if the cylinder is disconnected and removed from the
appliance. Cylinders must be stored outdoors out of the reach of children and must not be stored in a
building, garage or any other enclosed area. Your cylinder must never be stored where temperatures
can reach over 125°F / 51.5°C.
The maximum inlet gas supply pressure: 250 psi /1750 kPa.
Place a dust cap on cylinder valve outlet whenever the cylinder is not in use. Only install the type of
dust cap on the cylinder valve outlet that is provided with the cylinder valve. Other types of caps or
plugs may result in leakage of propane.
DO NOT obstruct the flow of combustion air and ventilation air to the fire pit.
The propane cylinder must be arranged for vapor withdrawal and equipped with a listed overfilling
prevention device. Please use the proper cylinder orientation to provide vapor withdrawal.
NOTE: The cylinder must be fully upright for the cylinder to have vapor withdrawal only.
CORRECT
a. Do not store a spare LP-gas cylinder under or near this appliance.
b. Never fill the cylinder beyond 80 percent full.
c. If the information in (a) and (b) is not followed exactly, a fire causing death or serious injury
may occur.
The pressure regulator and hose assembly supplied with the appliance must be used.
When an appliance is for connection to a fixed piping system, the installation must conform with local
codes, or in the absence of local codes with the National Fuel Gas Code, ANSI Z223.1 • NFPA 54;
National Fuel Gas Code; Natural Gas and Propane Installation Code, CSA B149.1; or Propane
Storage and Handling Code, CSA B149.2, as applicable.