Note: Please note that not all functions are possible in all
digital protocols. Several settings for functions, which are
supposed to be active in analog operation, can be done
under mfx and DCC.
Notes on digital operation
• The operating instructions for your central unit will give
you exact procedures for setting the different parame-
ters.
• The values set at the factory were selected to guarantee
the best possible running characteristics.
• The setting done at the factory does not permit operation
with opposite polarity DC power in the braking block.
If you want this characteristic, you must do without
conventional DC power operation (CV 29/Bit 2 = 0).
mfx Protocol
Addresses
• No address is required; each decoder is given a one-
time, unique identifier (UID).
• The decoder automatically registers itself on a Central
Station or a Mobile Station with its UID.
Programming
• The characteristics can be programmed using the
graphic screen on the Central Station or also partially
with the Mobile Station.
• All of the Configuration Variables (CV) can be read and
programmed repeatedly.
• The programming can be done either on the main track or
the programming track.
All manuals and user guides at all-guides.com
• The default settings (factory settings) can be produced
• Function mapping: Functions can be assigned to any of
DCC Protocol
Addresses
• Short address – long address – multiple unit address
• Address range:
• Every address can be programmed manually.
• A short or a long address is selected using the CVs.
• A multiple unit address that is being used deactivates the
Programming
• The characteristics can be changed repeatedly using the
• The CV numbers and the CV values are entered directly.
• The CVs can be read and programmed repeatedly. (Pro-
• The CVs can be programmed in any order desired. (Pro-
repeatedly.
the function buttons with the help of the 60212 Central
Station (with limitations) and with the 60213/60214/60215
Central Station (See help section in the Central Station).
1 - 127 for short address and multiple unit address,
1 - 10239 for long address
standard address.
Configuration Variables (CV).
gramming is done on the programming track.)
gramming can be done on the main track PoM). The PoM
can only be done with those designated in the CV table.
Programming on the main track PoM must be supported
by your central controller (Please see the description for
this unit.).