Télécharger Imprimer la page

Preparation - Hypertherm Powermax 1000 Mode D'emploi

Masquer les pouces Voir aussi pour Powermax 1000:

Publicité

Les langues disponibles

Les langues disponibles

GAS MANIFOLD REPLACEMENT

Preparation

Disconnect the power from the power supply and remove the torch lead. See Section 3 of the Operator Manual.
Remove the old manifold
1. Remove the 12 screws from the power supply cover and lift
off the cover.
2. Remove the screw from the ETR barrier and remove the
barrier.
3. Disconnect the gas hose
fitting. Compress the hose
fitting collar and pull the gas
hose from fitting.
4. Remove the solenoid wire connector from the power board
receptacle (J20).
2
2
2
ETR Barrier
Screw
3
Gas Hose Fitting.
1
Cover screws (12)
AMPS
40
60
25
80
AC
50
PSI
60
70
80
4.0
5.0
6.0
BAR
_
+
4
Solenoid Wire Connector.
Field Service Bulletin

Publicité

loading

Ce manuel est également adapté pour:

Powermax 1250Powermax 1650