Purpose; Intended Purpose; General Properties; Scope Of Supply - Dimplex LAW 9IMR Instructions D'installation Et D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

LAW 9IMR - LAW 14ITR
2

Purpose

2.1 Intended purpose

The indoor unit constitutes the interface between a reversible
heat pump and the heating system in the building. The indoor
unit contains all hydraulic components required between heat
generation and heat distribution with an unmixed heating cir-
cuit.

2.2 General properties

Low installation effort
Ready for use, contains all essential components via
pumps, shut-offs, safety technology and heat pump man-
ager
Integrated 300 l domestic hot water cylinder
Integrated 100 l buffer tank
The infinitely adjustable operation of the circulating pump
permits adjustment of the output according to need.
Optional immersion heater up to 6 kW
Switchable pipe heater (2 / 4 / 6 kW) for supplementary
heating.
3

Scope of supply

3.1 Indoor unit

Hydraulic components
Combined cylinder with integrated 100 l buffer tank and
300 l domestic hot water cylinder
Unmixed heating circuit including controlled circulating
pump
Shut-offs
2. Heat generator, electrical pipe heater, heat output 2 / 4 /
6 kW, secured via safety temperature limiter
Overflow valve
3-way reversing valve for generating domestic hot water
Safety equipment:
Safety valve, start-to-leak pressure 2.5 bar
Connection for external expansion vessel
Refrigerating equipment
Heat exchanger refrigerant / heating water
Connections for split line
www.gdts.one

3.2 Contact plate

ATTENTION!
Before opening the device, ensure that all electric circuits are
disconnected from the power supply.
The contact plate is in the top area of the indoor unit. After re-
moving the front cover, the electronics area is freely accessible.
The contact plate contains the supply connection terminals,
heating contactors, connecting terminals for the connecting
line to the heat pump and the heat pump manager.

3.3 Heat pump manager

The integrated heat pump manager is a convenient electronic
regulating and control device. It controls and monitors the en-
tire heating system based on the outdoor temperature, as well
as domestic hot water preparation and safety systems.
The enclosed operating instructions describe the functional
principle and use of the heat pump manager.
4

Transport

A pallet should be used to transport the heat pump to its final
installation location. The basic device can be transported with a
lift truck, a pushcart or similar.
ATTENTION!
The indoor unit is to be fixed to the transport pallet with
screws.
452162.66.04 · FD 9912
English
EN-3

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Law 14imrLaw 14itr

Table des Matières