Message
They point out that the gate has excee-
ded:
-(Err1), the max allowed number of
reversals (20) without ever reaching the
end of stroke (or stop) while closing;
-(Err2) the max number of uninterrupted
operations (5) of the anti-crush safety
device;therefore an "emergency maneu-
ver" is under way: the control board sets
the motors in a slow down phase and
searches the stops (or ends of stroke)
in order to reset the positioning system.
Once the stops (or ends of stroke) while
closing are found again the message
disappears and the control board awaits
further instructions "----" and then resu-
mes working normally.
External photocells and/or safety devices
are activated or out of order
The motors are not connected or it si-
gnals control board failure

9 MAINTENANCE

WARNING Any installation, maintenance or repair operation on the whole system must be carried
out exclusively by qualified personnel. All these operations must be performed only after disconnecting
the power supply, and operating in strict compliance with the electrical standards and regulations in
force in the nation of installation.
WARNING: With control boards range "RR" disconnect the power supply wires before
unlocking the operator manually. When you start the operator again the first operation
will bring the door to a complete closing. If you do not follow this procedure the door will
lose its right positioning.

10 PRODUCT DISPOSAL

WARNING Disposal of packaging materials (such as plastic, card board, etc.) must be done according
to regulations in force locally. Do not leave plastic bags and polystyrene within the reach of children
Demolition of this product does not cause particular dangers. Whenever the regulations in force in
the country of installation demand it, it is always advisable and necessary to dispose suitably and sepa-
rately of each material that make up the product: plastic, ferrous materials, batteries and electric parts.
ERROR MESSAGES
Description
Operating instructions and warnings
Possible solutions
In case the gate is not properly closed after the
emergency maneuver (maybe because of false
stops or obstacles due to mechanical frictions),
proceed as follows:
- Disconnect the power supply, check manually
that no particular frictions and/or obstacles are
present during the complete stroke of both leafs.
Leave both leafs half-open.
- Connect power supply and then give a START im-
pulse. At this point the wings will start closing until
their arrival at the stroke end (or limit switches).
Make sure that the maneuver is properly comple-
ted. If the gate keeps working improperly repeat
the motor stroke memorization procedure.
Adjust force and motor speed values, if needed
(see par. 8.2)
Make sure that all safety devices and/or photocells
installed are working properly.
Make sure that the motors are properly connected.
If the message reappears change the control board.