en
6.2
Electrical connection
➢ Observe the
Safety
Circuit board in lower part:
Connecting terminal (X1)
Connecting cables:
Operating voltage connection
Note: Devices with DC voltage are equipped with reverse polarity protection. No function if the polarity of the
connections is reversed.
6.3
Setting the operating modes
Circuit board in the lens:
Selection of operating mode
Light intensity control
Flashing light: 10 – 100%
Blinking- / Continuous light:
45 – 100%
06/2021
Operating instructions PY L-S-TL/ PY L-S-TLA
information!
AC: DC:
2
S1
X1 Operating voltage connection
X2 Plug connection light for combined
X3 Plug connection sounder
X4 Plug connection 1
X5 Plug connection 2
X6 Plug connection 3
L/
+
N/
-
st
1
stage
nd
stage
rd
3
stage
1
OFF OFF OFF
OFF OFF ON
OFF ON OFF
OFF ON ON
ON OFF OFF
ON OFF ON
ON ON OFF
ON ON ON
*
Factory setting
Page 6 /7
operation with sounder.
st
stage
nd
stage
rd
stage
S1
Operating mode
2
3
Flashing light 1 Hz
Flashing light 0.75 Hz
Continuous light
Blinking light
Flashing light 2 Hz
Blinking light
Flashing light 0.1 Hz
Flashing light 0.5 Hz
*
1 Hz
2 Hz
086200016d