Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 61
Loosen the screws on the terminals (04) on the front
of the connector, insert the conductors and fasten
them tightening the screws. Screw in the body of the
connector (03) to the front with the terminals (05),
tightening the ring nut (06).
Pay attention to the fixing. Tightening
torque: from 0.29Nm to 0.39Nm.
05
06
Fig. 19
Insert the gasket (02) inside the compartment of the
body of the connector (03). Lastly, fasten the sealing
nut (01).
03
Fig. 20
Pay attention to the fixing. Tightening
torque: from 0.39Nm to 0.59Nm.
Fig. 21
Complete assembly.
MNTCNVX_1915_EN
04
04
03
02
01
Before fastening the mobile connectors to the
relevant connectors on the back of the camera,
ensure the TAPS correspond.
Fig. 22
Connect the mobile connector on the fixed
connector and tighten the ring nut.

8.2.2 Relays connection

The relay is usable with the specifications
described below. Working voltage: to
30Vac or 60Vdc. Current: 1A max. Use
suitable cable sections with the following
characteristics: from 0.14mm² (26AWG) to
0.75mm² (18AWG).
The relay contacts are situated on the relevant quick
connector. The relays have no polarity (Tab. 1, page 
16).
17

Publicité

Table des Matières
loading

Table des Matières