8.2.1 Mobile connectors cabling (power
supply, I/O)
CONN 1
1
2
4
3
Fig. 17
Front view of the pins and internal view of the termi-
nals.
CONN 1 (4-POLE CONNECTOR)
Pin number
Function
1
Washer pump relay
2
Washer pump relay
3
Auxiliary relay (configurable relay)
4
Auxiliary relay (configurable relay)
Tab. 1
CONN 2 (5-POLE CONNECTOR)
Pin number
Function
1
Power supply 24Vac/24Vdc
2
Power supply 24Vac/24Vdc
3
Not used
4
Factory Default
5
Factory Default
Tab. 2
16
CONN 2
Use of cables with the following characteristics is
highly recommended:
• Section: from 0.14mm² (26AWG) to 0.75mm²
• Diameter: from 4mm (0.16in) to 8mm (0.3in).
1
2
• Length: 50m (164ft) max (24Vac or 24Vdc), 100m
The section of the conductors influences the
maximum permitted length for the cables. The
maximum length of the cables based on the section
of the conductors is outlined in the following table.
MAXIMUM CABLE LENGTH
Section
4
5
3
22AWG
20AWG
18AWG
Tab. 3
Cable the mobile connector by operating as follows.
Unsheathe the cable up to a maximum of 18mm. Peel
the conductors up to a maximum of 5mm.
Insert the cable using the sealing nut (01), the gasket
(02) and the body of the connector (03).
Fig. 18
Polarity of the voltage applied to pins 1 and
2 of the connector 2 is irrelevant.
Earthing is not planned since the product
does not require it when powered in 24Vac
or 24Vdc.
(18AWG)
(328ft) max (PoE+)
Without board for
video analysis
20m (66ft)
30m (98ft)
50m (164ft)
03
02
With board for
video analysis
15m (49.2ft)
25m (82ft)
40m (131ft)
01
MNTCNVX_1915_EN