Connection Of The Power Supply Line; Connection Of The Power Supply Line, 24Vac/24Vdc (Version Of The Product Not Cabled); Connection Of The Power Supply Line, Poe+ (Version Of The Product Not Cabled); Connection Of The Power Supply Line, 24Vac/24Vdc (Version Of The Product Cabled) - Stahl EC-910-AFZ Serie Manuel D'instructions

Masquer les pouces Voir aussi pour EC-910-AFZ Serie:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 65
6.6 Connection of the power
supply line
6.6.1 Connection of the power supply
line, 24Vac/24Vdc (version of the
product not cabled)
Check that the power supply socket and
cable are adequately dimensioned.
The polarity of the voltage, applied to the
power terminal, is irrelevant.

CONNECTION OF THE POWER SUPPLY LINE

Power supply 24Vac/24Vdc
Colour
Terminals
Defined by the installer
~/+
Defined by the installer
~/-
Tab. 6
CABLES SPECIFICATIONS
Cable section
Supply voltage
1.5mm² (16AWG)
24Vdc
24Vac
Tab. 7
The power supply cable must be covered
by the silicone sheath (01) supplied. The
silicone sheath must be fastened with the
corresponding cable tie (02).
N/-
L/+
Fig. 21
The power supply cables should be connected to the
power supply terminal of the housing board (J1, 6.5
Housing board description, page 18).
6.6.2 Connection of the power supply
line, PoE+ (version of the product not
cabled)
The product can be powered using PoE+ (Power
Over Ethernet) devices in compliance with the
international standard for technological information
IEEE 802.3at, using an Ethernet data cable Category
5E.
MNTCMMX_2040_EN
Cable section
from 0.14mm² (28AWG)
up to 1.5mm² (16AWG)
from 0.14mm² (28AWG)
up to 1.5mm² (16AWG)
Maximum cable
length
20m (66ft)
40m (131ft)
01
02
Maximum Ethernet cable length (category
5E): 100m.
The PSE (Power-Supplying Equipment) devices
suitable for the product power supply must comply
with the standard IEEE 802.3at (PoE+).
The Ethernet cable should be connected to
connector RJ45 of the housing board (J8, 6.5 Housing
board description, page 18).
The Ethernet cable shield must always be
earthed via the connector. Always use a
shielded RJ45 connector.
Carry out the connections as described in the table
(according to the standard: TIA/EIA-568-B).
CONNECTION OF THE ETHERNET CABLE
Pin number
Cable colour
1
Orange-White
2
Orange
3
Green-White
4
Blue
5
Blue-White
6
Green
7
Brown-White
8
Brown
Tab. 8
6.6.3 Connection of the power supply
line, 24Vac/24Vdc (version of the
product cabled)
Perform the connections following the instructions
reported in the table .
CONNECTION OF THE POWER SUPPLY LINE (24VAC/24VDC)
Colour
Function
Black 1
~/+
Black 2
~/-
Tab. 9
6.6.4 Connection of the power supply
line, PoE+ (version of the product
cabled)
The product can be directly connected to an
Ethernet switch equipped with a PoE+ (End-Span
configuration) port or a classic Ethernet switch using
a PoE Injector (Mid-Span configuration).
Cable section
1.5mm² (16AWG)
1.5mm² (16AWG)