• Handle the product with care to avoid accidental
contacts, sharp edges and corners.
• The main insulation must be set up externally to
the product by a safety transformer and/or an
insulated direct current power supply unit.
• To feed the product use a safety transformer
and/or a voltage isolated power supply with the
appropriate characteristics. The characteristics
of output power must not exceed the following
values. Supply voltage: 24Vac (±10%) or 24Vdc
(±5%).
• A power disconnect device must be included
in the electrical installation, and it must be very
quickly recognizable and operated if needed.
• For technical services, consult only and exclusively
authorized technicians.
• Use adequate personal protective equipment
during installation.
• Comply with all the national standards during the
device installation.
8
• This is a Class A product. In a domestic
environment this product may cause radio
interference. In this case the user may be required
to take adequate measures.
• Connect the device to a power source
corresponding to the indications given on the
marking label. Before proceeding with installation
make sure that the power line is properly isolated.
• To comply with the main supply voltage dips and
short interruption requirements, use a suitable
Uninterruptable Power Supply (UPS) to power the
unit.
• Power the device using a mains power supply
24Vac, 24Vdc or, for models without a board for
video analysis, a PSE (Power Sourcing Equipment)
in compliance with IEEE 802.3at (PoE+).
• In the case of a 24Vac power supply, you must
provide for adequate separation from the AC
power supply line using double or reinforced
insulation between the main power supply line
and the secondary circuit.