Starting The Engine: Gasoline; Starting The Engine: Propane; Switching Fuel Sources - Westinghouse WGen12000DFc Manuel De L'utilisateur

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

OPERATION
Fire and explosion hazard. DO NOT move or tip the
generator during operation.

STARTING THE ENGINE: GASOLINE

During Push-Button or Remote Start the engine will
automatically set the choke and begin the start sequence.
If the engine fails to start, the generator will attempt to
start the engine two more times. The battery switch can be
turned off at any time during the automatic start sequence
to abort the engine start attempt.
If the cranking speed drops after each unsuccessful
attempt, then the battery may not be adequately charged.
See BATTERY MAINTENANCE
1. Verify that fuel is in the gas tank.
2. Turn the fuel selector switch to gasoline operation.
3. Turn the fuel tank valve to the ON position.
4. Push the battery switch to the ON position.
5. Choose the starting method:
a. Remote Start: Push and hold the START button on
the remote start key fob for one second.
Note: Remote start-equipped generators must be restarted
with the START/STOP switch on the control panel
after an automatic shut-down occurs.
b. Push-Button Start: Push and hold the engine
START/STOP button for two seconds.
20 | Westinghouse Outdoor Power Equipment
section.

STARTING THE ENGINE: PROPANE

Fire and explosion hazard. Always turn the propane
tank valve to the fully closed position if not operating the
generator on propane.
1. Make sure the LPG/propane hose is correctly connected
to the generator and propane tank.
2. Turn the fuel selector switch to propane operation.
3. Fully open the valve on the propane tank.
4. Push the battery switch to the ON position.
5. Choose the starting method:
a. Remote Start: Push and hold the START button on
the remote start key fob for one second.
b. Push-Button Start: Push and hold the engine
START/STOP button for two seconds.

SWITCHING FUEL SOURCES

Fire and explosion hazard. DO NOT add gasoline to
the fuel tank or connect the LPG/propane hose to the
generator while the generator is in operation.
The fuel source can be switched while the engine is
running if a propane tank is connected to the generator
BEFORE operation.
Note: Switching fuel sources while over 50% load capacity
may cause the engine to stop. If the engine stops
when switching fuel sources, disconnect all loads
then restart the unit on the fuel source of choice.
GASOLINE TO PROPANE
IMPORTANT: Load capacity is reduced when running
on propane. Make sure the generator can
supply enough (running) and surge (starting)
watts for the items you are powering before
switching to propane.
1. Fully open the valve on the propane tank.
2. Turn the fuel selector switch to propane operation.
3. Turn the fuel tank valve to the OFF position.
PROPANE TO GASOLINE
1. Turn the fuel tank valve to the ON position.
2. Turn the fuel selector switch to gasoline operation.
3. Turn the propane tank valve to the fully closed position.