RMD10
Please note the following information:
Item in
fig. i,
Description
page 9
1
Screw M4 (Torx TX20),
Tightening torque: 2 Nm
2
Refrigerator gas connection:
M14 x 1.5 (d = 8 mm/ISO8434 (DIN2353)
3
Gas pipe with ring coupling (size 17),
Tightening torque: 25 Nm
➤ Have a leak test and a flame test performed by an authorized specialist after
professional installation.
Ensure you are issued with a certificate of inspection.
6.2
Connecting to DC and AC
A
NOTICE!
The electrical installation and repairs may only be performed by a
specialist in accordance with the applicable regulations and stand-
ards.
The respective negative and positive cables of the DC connections
for heating and lighting may not be joined with one another in a
camper. This can cause electrical interference or damage to electri-
cal components.
EN
Connecting the refrigerator