Converting Appliances For Use With Ng Gas; Pressure Regulator Conversion - Fulgor Milano SOFIA Instructions D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Proceed to Pressure Regulator Conversion noting the LP /
Propane position to complete the conversion.
After replacing the injectors adjust the burner flame (see Low
Flame Adjustment paragraph).
Check the appearance of each burner's flame at HILO settings,
if the flame appears too large or too small make sure that all
steps were completed correctly.

Converting Appliances for Use with NG Gas

If this appliance should be converted for use with gas NG
(natural gas), each of the following modifications must be
performed.
1. Convert the pressure regulator to NG position as per the
section "Pressure Regulator Conversion".
2. Replace all injectors following the step described on the
previous pages, observe the number stamped on the side,
this number corresponds to the orifice diameter and its
correct burner location (refer to the illustrations in section:
"Injectors Position").
3. Adjust the burner flame (see Low Flame Adjustment section).
Check the appearance of each burner's flame at HI - LO
settings, if the flame appears too large or too small make sure
that all steps were completed correctly.

Pressure regulator conversion

The appliances is designed for use with NG gas or LP gas. The
gas pressure regulator is supplied. It must be installed in the
gas supply line ahead of the manifold entrance.
It is pre-set for use with the gas as indicated on the appliance
label supplied with the appliance. For use with different gas
the appliance must be converted.
For the pressure regulator conversion follow the instructions
below:
• Disconnect all electrical power, at the main circuit breaker
or fuse box.
• Shut off the gas supply to the cooktop by closing the manual
shut-off valve.
• Adjust the pressure regulator, by following the instruction
(see figure)
1. Unscrew the regulator cap
2. Unscrew the plastic conversion plug from the cap turn
over and screw back (wide section away from cap for
LP and against cap for NG) see figures below.
3. Replace the regulator cap ensuring gasket is in place.
All manuals and user guides at all-guides.com
6 - Conversion for LP or NG Gas
PRESSURE REGULATOR CONVERSION
NG POSITION
PLUG
NG
Before replacing the regulator cap, check if the
position of plug is suitable for the gas
EN
CAP
GASKET
LP/PROPANE
POSITION
PRESSURE
REGULATOR
LP
15

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

F6pgr366s1

Table des Matières