Replace Injector On (Oven Lower Burner); Conversion For Lp Or Ng Gas - Fulgor Milano SOFIA Instructions D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Replace injector on (oven lower burner)

1. Remove the burner cover plate.
2. Disconnect both heat sensor and the ignition spark plug.
3. Remove the screw securing the oven burner and withdraw
the burner from the support.
All manuals and user guides at all-guides.com

6 - Conversion for LP or NG Gas

4. Remove the nozzle by turning 9-32" nut driver counter
clockwise.
5. Install the injectors supplied with this appliances in the
appropriate burner. The injectors have small number
stamped on the side, this number codes the orifice diameter
and its correct burner location (see figure of the paragraph
"Injectors position").
6. Turn clockwise to tighten (tighten to a torque of 15 to 20
inch-lbs)
7. Replace all parts following the reverse order. Save the
injectors removed from the appliances for future use.