event of escape of the liquid. In this situa-
tion, turn off the pump and leave the sys-
tem to cool.
Never use the pump in the event
of cavitation, as this can cause
damage to the hydraulic compo-
nents.
Pressure on the downline side of
the pump (delivery side) must
never exceed the maximum op-
erating pressure PN as indicated on the
pump data plate (see "Application Limits"
Figure 3). Pressure downline of the pump
is obtained from the sum of the pressure
delivered and the pressure on the suction
side (gravity for installations with negative
suction head, aqueducts, or water system
where admissible or required).
1. Check that the shutoff valves downline
of the pump (delivery side) and upline
of the pump are in the open position.
2. When the pump is connected to the
power supply it runs a "starting pha-
se". The green led
FLOTEC logo shows up on the di-
splay (a) As this first phase ends,
the pump is not operating and the
display shows the writing STOP(b)
(a)
LINE
RUN
FAULT
MODE
24 24
is ON and the
SET
ESC
(b)
LINE
STOP
STOP
RUN
FAULT
MODE
3. Start
the
sing
on
the
LINE
RUN
FAULT
MODE
The pump starts and reaches the
pressure level set in the factory. The
RUN/FAULT
en color. In case the system pressu-
re is "higher than" or "equal to" the
factory pressure setting, the pump
is in stand-by (green led ON), rea-
dy to start if the pressure decreases.
4. If the pump does not start properly and
does not quickly reach the working
conditions, then STOP the pump. The
pump could switch to PROTECTION
mode, please see chapter " QUICK
TROUBLE SHOOTING GUIDE"
5. Repeat the pump priming operations
Programming:
1. Language setting:
SET
ESC
pump
by
ON/OFF
SET
ESC
led is ON and in gre-
pres-
button.