Control Adjustments

LCD DISPLAY
MODE BUTTON
Figure 29. Control Adjustments

Control Panel Removal

To remove the ignition control board from the heater, use
the following procedure:
1. Turn off main power to the heater.
2. Remove front door to access wire harnesses.
3. Reaching underneath the ignition board, carefully
remove all connectors and wires from the ignition
board and ON/OFF toggle switch.
4. Lift the front bezel lid and remove the two lower
Phillips screws.
5. Carefully lift the control panel upwards and pull away
from the heater.
6. The control panel can now be flipped around to
remove or inspect the ignition board.
7. Reverse procedure for re-installation.
Figure 30. Removing the Ignition Control Board
28
TEMP ADJUST
BUTTONS
ON
OFF
F10342
F10343
Thermostat Operation -
Ignition Control Board
Figure 31. Ignition Control Board
Controls Operation
The pool heater touchpad, located on the upper portion
of the angled corner panel of the heater, allows the
user to select the mode of operation, adjust the setpoint
temperature, configure the heater controls and access
diagnostic information. The LCD display window indicates
the mode (OFF, SPA, POOL, MANUAL, SCHEDULE A/B),
the water temperature and if applicable the heater setpoint
and current operating condition. A manual power switch
provided turns the control power ON or OFF.
Mode Selection
The MODE button is used to select POOL, SPA, MANUAL
OVERRIDE or RUN SCHEDULE operation. It also allows
the user to turn the heater off electronically by selecting the
OFF mode, allowing the LCD display to remain energized
and to continue showing the actual water temperature.
POOL and SPA Modes
In either POOL or SPA mode, the mode, day of week
and time are displayed on the top line of the display. The
current water temperature, desired water temperature
(SETPOINT), and current status are shown alternating on
the lower line of the display. The temperature SETPOINT
can be adjusted using the UP or DOWN buttons. In POOL
mode, the setpoint range is 50°F to 104°F (10°C to 40°C).
In SPA mode, the setpoint range is 50°F to 107°F (10°C
to 42°]C).
In either POOL or SPA modes, the heater will operate to
maintain the desired water temperature, turning the heater
on when the temperature falls below the setpoint and
turning the heater off when setpoint temperature is reached.
Filter pump, motorized valve, auxiliary outputs and heating
operation will operate according to INSTALLER SETUP
MODE settings (See page 29).

MANUAL OVERRIDE

MANUAL OVERRIDE mode allows manual operation
of controller functions for up to 24-hours. The user may
PROGRAM
BUTTON