IO-Link interface (continued)
System commands
Index
Name
(dec)
0x0002
System
(2)
Command
Error codes
14
english
Data
Access
Value range
format
UINT8
W
0x01 (1) =
ParamUploadStart
0x02 (2) =
ParamUploadEnd
0x03 (3) =
ParamDownloadStart
0x04 (4) =
ParamDownloadEnd
0x05 (5) =
ParamDownloadStore
0x06 (6) =
ParamBreak
0x40 (64) =
Teach Apply
0x41 (65) =
SP1SingleValueTeach
0x42 (66) =
SP2SingleValueTeach
0x4F (79) =
Teach Cancel
0x80 (128) =
Device Reset
0x82 (130) =
Restore Factory Settings
0xA2 (162) =
BDC Reset
0xA5 (165) =
Reset Operating Hours
0xA6 (166) =
Reset Counter
Error code
0x8011
0x8012
0x8020
0x8021
0x8022
0x8023
0x8030
0x8033
0x8034
0x8035
0x8036
Block
Parameterization
Teach Channel
Reset
Description
Index not available
Subindex not available
Service temporarily not available
Service temporarily not available – Local control
Service temporarily not available – Device control
Access denied
Parameter value out of range
Parameter length overrun
Parameter length underrun
Function not available
Function temporarily unavailable
Remarks
Start Parameter Upload
Stop Parameter Upload
Start Parameter Download
Stop Parameter Download
Stop block parameter
download and set Upload
Request
Cancel block parameterizing
Save and apply switch point
Teach TP1 of SP1
Teach TP1 of SP2
Cancel Teach-In
Reset device
Reset sensor parameters to
factory defaults
BDC addressed by Teach-In
channel to factory defaults
Reset individual operating
hours counter to 0
Reset counter value