1. Part of metal ground strap must be cut out and removed.
A. Metal ground strap
B. Discard
C. Ground-link screw
2. Use a 5/16" (7.9 mm) nut driver to remove the ground-link
screw from the back of the range. Save the ground-link
screw and the end of the ground link under the screw.
3. Pull the wires through the strain relief on bottom of range.
Allow enough slack to easily attach wiring to the terminal
block.
When direct wiring, relocate the conduit bracket so the left
hole is centered beneath the terminal block.
A
D
E
F
A. Terminal block
B. Ground-link screw
C. Conduit Bracket
D. Bare (green) ground wire
E. Line 2 (red) wire
A
B
C
B
C
H
I
G
J
F. Neutral (white) wire
G. Line 1 (black) wire
H. Removable retaining nut
I. Power Cord Strain Relief
J. Direct Wire Strain Relief
4. Attach terminal lugs to line 1 (black), neutral (white), and line
2 (red) wires. Loosen (do not remove) the setscrew on the
front of the terminal lug and insert exposed wire end through
bottom of terminal lugs. Securely tighten setscrew to torque
as shown in the following Bare Wire Torque Specifications
chart.
C
D
A. Terminal lug
B. Setscrew
C. Line 2 (red) wire
D. Neutral (white) wire
E. Line 1 (black) wire
Bare Wire Torque Specifications
Attaching terminal lugs to the terminal block - 20 lbs-in. (2.3
N-m).
W
i
e r
A
w
g
8 gauge copper
6 gauge aluminum
5. Use a hex or 5/16" (7.9 mm) nut driver to connect the bare
(green) ground wire to the range with the ground-link screw
and ground-link section. The ground wire must be attached
first and must not contact any other terminal.
6. Use ³⁄
" (1.0 cm) nut driver to connect the neutral (white) wire
8
to the center terminal block post with one of the 10–32 hex
nuts.
A
B
C
A. 10-32 hex nut
B. Line 2 (red)
C. Bare (green) ground wire
D. Ground-link screw
7. Connect line 2 (red) and line 1 (black) wires to the outer
terminal block posts with 10-32 hex nuts.
8. Securely tighten hex nuts.
9. Replace terminal block access cover.
A
B
E
T
o
q r
u
e
25 lbs-in. (2.8 N-m)
35 lbs-in. (4.0 N-m)
G
F
D
E
E. Neutral (white) wire
F. Line 1 (black)
G. Terminal lug
11