Possible Switching Modes Of The 8311 - Burkert 8311 Manuel Utilisateur

Masquer les pouces Voir aussi pour 8311:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

.6 Possible switching modes of the 8311

Hysteresis mode
The change of state occurs when a threshold is detected
(increasing pressure: high threshold (OHI) to be detected,
decreasing pressure: low threshold (OLO) to be detected)
Contact
Not inverted
ON
OFF
Pressure
OLO OHI
Window mode
The change of state occurs when any thres-
hold is detected
Contact
Not inverted
ON
OFF
Pressure
OLO OHI
The delay (dEL) is set for the both switching
thresholds. The switching only occurs when
either threshold value (OHi - OLO) is excee-
ded for a duration higher than the dEL delay.
8311
Contact
Inverted
ON
OFF
Pressure
OLO OHI
Contact
Inverted
ON
OFF
Pressure
OLO OHI
Pressure
OHI
OLO
hysteresis mode
Not inverted
Inverted
DEL = 0 s
Not inverted
Inverted
DEL = 2 s
Window mode
Not inverted
Inverted
DEL = 0 s
Not inverted
Inverted
DEL = 2 s
Switching examples of the 8311 depending on
the pressure and the switching mode chosen
21
2 s
2 s
OUT
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
2 s
t

Publicité

Table des Matières
loading

Table des Matières