SERVICE
TO GAIN ACCESS TO VALVE FOR SERVICING
• Remove HANDLE (see step 3 and reverse).
• Remove ESCUTCHEON and CARTRIDGE CAP (see step 1 and reverse).
VALVE LEAKS WHEN SHUT OFF
• Remove CARTRIDGE, see STEP 1 and STEP 2 and REVERSE process.
• Clean SEALS on the side of CARTRIDGE. Clean inside sealing surface of VALVE BODY.
• Re-assemble CARTRIDGE. Install trim. Turn on water supply and check for leaks.
REPLACING CARTRIDGE
• To remove CARTRIDGE (1), install split WASHER (3) between the ridge on the cartridge and the bonnet nut.
(only supplied with replacement cartridge). as shown.
• Proceed to unthread BONNET NUT (2) counter clockwise.
Note: CARTRIDGE (1) should be pulling out while unthreading BONNET NUT (2).
Upon removal of the old Cartridge, install a new cartridge and secure it with
BACK TO BACK INSTALLATION
• Remove CARTRIDGE (B) as detailed in steps above.
• Remove PIN (A) from CARTRIDGE (B) by pulling.
• Separate MANIFOLD (C) from CARTRIDGE (B) by pulling.
• Rotate CARTRIDGE (B) 180 degrees and reinstall MANIFOLD (C) with PIN (A).
• The "UP" TEXT (D) should now be facing downward during installation of the CARTRIDGE (B).
7

CARE INSTRUCTIONS:

DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
2
3
Turn off hot and cold water
CAUTION
supplies before beginning.
Standard
BACK TO BACK INSTALLATION
1
B
1
B
3
- 4 -
(Hand tighten).
BONNET NUT
Back to Back
180º
A
B
B
D
A
M965964 Rev. 1.1 (3/20)
C
2
4

Publicité

Table des Matières
loading

Table des Matières