Care Instructions - American Standard EDGEWATER 4932.300 Instructions D'installation

Masquer les pouces Voir aussi pour EDGEWATER 4932.300:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

5
TEST INSTALLED FAUCET
• Move HANDLE (1) into "off" position.
• Turn on water supplies.
• Check connection for leaks. (See Section 4)
• With HANDLE (1) in "off" position, unthread
SPRAY (3) from HOSE (2).
• Operate handle back to front, in COLD
and HOT positions, to flush water lines
thoroughly.
• Replace SPRAY (3) onto HOSE (2).
6
SERVICE
If faucet drips, operate HANDLE several times from "off" to "on." Do not apply excessive force.
Clogged CARTRIDGE outlets or inlets may cause reduced flow.
To clean, first turn off water supply then:
• Loosen HANDLE SCREW (1) and remove HANDLE (2).
• Unthread the SNAP RING (3). Unthread three
MOUNTING SCREWS (4).
• Lift CARTRIDGE (5) off MANIFOLD (6).
• Clean MANIFOLD (6) and CARTRIDGE (5) ports.
• Place CARTRIDGE (5) onto MANIFOLD (6) and
tighten MOUNTING SCREWS (4) alternately.
• Replace SNAP RING (3), HANDLE (2),
tighten HANDLE SCREW (1).
7

CARE INSTRUCTIONS:

DO: CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
2
3
REMOVE
6
- 3 -
HOT
OFF
ON
COLD
1
5
4
3
M965717 Rev. 1.8 (5/21)
1
2

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Edgewater 4932.307

Table des Matières