INSTALL HANDLE

• Hold ADAPTER (1) onto VALVE STEM (2) and install
ADAPTER SCREW (3) through ADAPTER (1) into
VALVE STEM (2).Tighten ADAPTER SCREW (3) to
secure ADAPTER (1) to VALVE STEM (2).
• Install HANDLE BASE (4) onto ADAPTER (1). Insert
SET SCREW (5) into HANDLE BASE (4). Align
HANDLE BASE (4) and tighten with HEX
WRENCH (6) supplied.
5
ADJUST HOT LIMIT STOP
• By restricting HANDLE rotation and limiting the amount
of hot water allowed to mix with the cold, the HOT LIMIT
SAFETY STOP (1) reduces risk of accidental scalding.
To set the maximum hot water temperature of your
faucet valve, adjust the setting on the HOT LIMIT
SAFETY STOP (1).
• Turn CARTRIDGE STEM (2) to the OFF position (coldest
setting) before making adjustment to HOT LIMIT STOP
(1). Pull forward and rotate counterclockwise one
number to limit hot water temperature. Use NUMBERS
(5) on CARTRIDGE (4) on HOT LIMIT STOP (1) for
indication.
3
4
5
6
4
1
COLDER
(Larger Numbers)
1 2 3 4 5 6 7 8 9 10
- 3 -
1
2
5
2
HOTTER
(Smaller Numbers)
1 2 3 4 5 6 7 8 9 10
3