7. 4. 2 WASHING
IMPORTANT
If the power supply cable is damaged, it must be replaced
by the manufacturer or by its service centre, or in any
case by similar qualified professionals, in order to avoid
all risk.
ATTENTION
Before performing any cleaning, always disconnect the
dispenser from the electricity supply by unplugging it or
turning off the external wall switch.
1 Fill a basin with approximately one gallon of hot water (45-
60°C) and 1 oz of specific detergent equipped (stera sheen
green label); indeed, a solution that is too concentrated may
damage the parts to be washed, whereas one that is too diluted
may not clean properly. Do not use any abrasive detergents.
IMPORTANT
In order to avoid damaging the dispenser, only use deter-
gents that are compatible with plastic components.
2 In order to avoid damaging the dispenser, only use
detergents that are compatible with plastic components.
ATTENTION
When cleaning the dispenser, do not use large quantities
of water in the vicinity of electrical components; if you
do, this may cause electric shocks or damage the
dispenser.
3 Wash the evaporator cylinder, the upper tank and the
connecting pipe using the brush supplied with the unit.
4 Rinse all washed parts under running water.
7. 4. 3 SANITIZING
Sanitising must be performed immediately prior to
operating the dispenser; avoid leaving it unused for any
length of time after sanitising.
Sanitization must be performed whenever the distributor is
put back into operation with a new product.
1 Before beginning the procedures described below, wash
your hands with anti-bacterial soap.
2 In a basin, prepare approximately two gallons of hot water
(45-60°C) and 2 ozs of sanitiser equipped (stera sheen green
label).
3 Soak all the parts to be sanitised into the solution for the
amount of time specified by the product manufacturer.
4 Allow to dry all sanitised parts in the open air, on a clean
surface.
5 Dry all the external parts of the dispenser without using
abrasive cloths.
7. 4. 4 ASSEMBLY
1 Insert the drip tray back in its seat.
IMPORTANT
Lubricate the tap piston, the scraper fitting and the front
of the scraper in the points indicated in figure using only
the grease provided with the machine or other grease for
foodstuff.
2 Reassemble the coupling and the scraper in the reverse
order to disassembly.
3 Reassemble the tap assembly in the reverse order to that
illustrated in Figure 20 and reposition it in its seat.
4 Screw both knobs back on, tightening them carefully.
5 Reassemble the front panel. (see figure 26)
6 Fit the mixer together taking care to insert the ends in the
21
figure 26