Connect Gas Supply - Bosch NGM8657UC Manuel D'installation

Masquer les pouces Voir aussi pour NGM8657UC:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Cooktop
A
Countertop
B
Wooden block
C
Required for installation in countertops that are
between 2" (50 mm) and 2¾" (70 mm) thick.
Long adjusting screw
D
Required for installation with wooden block
available for purchase from Customer Service
(order no. 10011930).
NOTICE: Do not use silicone to glue the cooktop to the
countertop surface.

Connect Gas Supply

Side View Gas Cooktop Installation
Gas and Electrical Location
Cooktop Rough-in Box
A
Arrow on Pressure Regulator
B
Pressure Regulator
C
1/2" Female Pipe Threads
D
Flexible Gas Line
E
Power Cord (40"/1 m)
G
120 Volt Receptacle
H
Gas Cut-off Valve
J
Gas Supply Line Stub-out
K
Floor
L
Installing the Pressure Regulator
WARNING
9
Do not attempt any adjustment of the pressure
regulator, except when converting to propane.
Adjustments could lead to leaks or cause incorrect
gas pressure to the appliance.
Install the pressure regulator (supplied with unit) to
manifold pipe using Teflon tape on threads of manifold
pipe. Turn to hand tighten plus 1/4 turn, not exceeding
1 turn for alignment.
To prevent possible damage to the gas pressure
regulator, install it after the cooktop is in its permanent
position. When the regulator is securely installed on the
manifold pipe, the conversion nut will be easily
accessible.
For tight installations a suitable kit is available from
Customer Service (order no. 00611084)
Appliance Manifold Connection
A
Conversion Nut
B
Pressure Regulator
C
Connecting the Gas Supply Line
Connect the gas supply line to the unit pressure
regulator using a ½" metal flex gas line or fixed metal
pipe connection between manual shut-off valve and
pressure regulator. Always install a new gas connection.
Checking Gas Line for Leaks
Check supply line connections for leaks using a soap
solution or non-corrosive leak detection fluid. Do not use
a flame of any sort.
Turn on gas.
1.
Apply a soap solution or non-corrosive leak detection
2.
fluid to all joints and fittings in the gas connection
between the shut-off valve and the cooktop. Include
gas fittings and joints in the cooktop if connections
may have been disturbed during installation.
Bubbles appearing around fittings and connections
indicate a leak.
If a leak appears, turn off supply line gas shut-off valve
3.
and tighten connections.
Retest for leaks by turning on the supply line gas shut-
4.
off valve. When leak check is complete (no bubbles
appear), test is complete.
Wipe off all soap solution or detection fluid residue.
5.
9

Publicité

Chapitres

Table des Matières
loading