Simu T3.5 E Hz.02 DC Mode D'emploi page 11

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4
Programming the first individual point of control
This operation can only be performed from the transmitter that was used for operation
- Press the transmitter "PROG" Key for approximately 1 second. The
motor will run for 0,5 second in one direction and then in the other. Your
transmitter is now programmed to control the motor in stable mode,
all the functions described in §6 are active.
5
Programming a new (individual, group or main) control point:
5.1 - Open the memory of the motor from the control transmitter:
- Press the "PROG" key of the transmitter for about 3 seconds. The motor
will run for 0.5 second in one direction and then in the other.
5.2 - Validate the operation from the new transmitter you want to
programm:
- Press the "PROG" key of the transmitter for about 1 second. The motor
will run for 0.5 second in one direction and then in the other.
- For group controls, repeat operations 5.1 and 5.2 for each motor in the group.
- For main controls, repeat operations 5.1 and 5.2 for each motor in the installation.
- To delete an transmitter from the memory of a motor, perform operations 5.1 with a programmed transmitter, then perform
the operation 5.2 with the transmitter to be deleted.
6
T3.5 EHz.02 DC motor functions
6.1 - With a well charged battery, the possible commands are: UP, STOP and DOWN. It is also possible to set an interme-
diate position (see §7).
6.2 - Frost detection function: The motor stops if the shutter is jammed by ice during opening.
6.3 - Detection of obstructions function: Jamming of the shutter due to the presence of an obstruction when closing the
shutter causes the motor to stop and then run in the reverse direction.
- If the voltage is below 10,2V: The motor will pause at the beginning of each command to lift the shutter. The shutter can
only be closed by pressing several times on the down button.
- If the voltage is below 9,3V: The motor won't accept any commands.
Operation of the motor will return to normal only if the battery voltage goes above 10,5V.
7
Recording / controling / deleting intermediate position
Recording:
- Position the motor on the wanted position.
- Press 5 seconds on the "stop" key. The motor will run for 0,5 second
in one direction and then in the other.
Controling:
- Press on the "stop" key for 0.5 s. the motor goes to the intermediate
position.
Deleting : Position the motor on the intermediate position. Press 5 seconds on the Stop key, the intermediate
position is deleted.
1
>>
5s
0.5s
3.1b.
3/4

Publicité

Table des Matières
loading

Table des Matières