3
End limits adjustment
During the operations in this section (§3), do not work on several motors at the same time.
Power supply by batteries :
- The voltage across the motor must be between 10,2 and 15 V. In any case should it be over 15 V (risk of destruction of
the motor).
- The voltage at the motor must not drop below 9,3 V during operation.
- The current delivered on the Solar panel input should not exceed 130mA. (risk of destruction of the motor)
3.1
a- Connect the battery to the motor.
Then, connect the solar panel to the motor.
b- Press simultaneously on the UP and DOWN buttons of a Hz transmitter. The motor
turns 0.5 second in one direction, then in the other. This transmitter now controls
the motor in unstable mode. Go to step 3.2
3.2- Adjustement of the end-limits: memorizing the end points: The end-limit adjustement can be done in two ways:
- First you can memorize the DOWN position (a) and then the UP position (b).
- First you can memorize the UP position (b) and then the DOWN position (a).
a
1
1- Position the motor on the DOWN end limit using the
"DOWN" and "UP" keys.
2- To memorize the DOWN end limit position, press simul-
taneously the "STOP" and "UP" keys. The motor will run
automatically in the "UP" direction.
3- Before the motor reaches the UP end limit, press
the"STOP" key.
4- After the adjustment of the DOWN (a) and the UP (b) end limits, confirm the settings:
- Press 2s on the "STOP" key to validate the settings. The motor will stop and will run for 0,5
second in one direction and then in the other. Go to next step.
If you do not want to use this transmitter as the individual control:
- cut the power supply (2 seconds minimum).
- repeat the opération 3.1* with a new transmitter and then go to step §4.
* In this case, the motor will run for 0,5 second in both directions, that means the limits setting is already done.
2/4
Connector: in accordance
with document SIMU : DOC115935
battery 12V LI-ION
2
3
&
Black
➀
➂
Fuse 3.15 AT
Brown
➁
Blue
➃
b
1
1- Position the motor on the UP end limit using the "UP" and
"DOWN" keys.
2- To memorize the UP end limit position, press simulta-
neously the "STOP" and "DOWN" keys. The motor will
run automatically in the "DOWN" direction.
3- Before the motor reaches the DOWN end limit, press the
"STOP" key.
+
➁
–
➀
➁
➂
➀
➃
Solar panel
Battery
2
4-
2s
–
➂
+
➃
3