Filling the cleaning fluid container
♦
Fill the cleaning fluid container
the desired mark .
NOTE
♦
The maximum water temperature is 30 °C .
Please observe the instructions of the cleaning
agent manufacturer . If a lower temperature is
indicated, use only this temperature .
If necessary, you can add water-soluble,
non-foaming cleaning agents . For the exact
mixing ratio, follow the instructions of the
cleaning agent manufacturer .
♦
Do not use acidic, alkaline or easily flammable
cleaning agents .
♦
The compressed air cleaning gun atomizes
the cleaning fluids into micro-fine droplets .
Use
♦
The surface to be cleaned must be roughly
cleaned before use .
♦
Turn the valve
to the vertical position in order
to switch on the cleaning fluid from the cleaning
fluid tank
.
The valve
is infinitely variable, so that the
amount of cleaning fluid is increased or re-
duced, depending on the setting of the
valve
.
♦
Keep the compressed air cleaning gun at a
distance of 1–3 cm from the surface to be
cleaned .
♦
Press and hold the trigger
compressed air cleaning gun .
♦
In order to achieve an optimal result, move the
brush
of the compressed air cleaning gun in
smooth, circular movements over the surface to
be cleaned .
♦
To finish working, release the trigger
PDRP 6.2 B2
All manuals and user guides at all-guides.com
with water to
to activate the
.
♦
After finishing the work, wipe the surface dry,
switch off the compressor and disconnect the
compressed air hose from the compressed air
cleaning gun .
♦
Afterwards, unscrew the cleaning fluid tank
from the compressed air cleaning gun and
dispose of the contents in an environmentally
friendly manner .
Maintenance and cleaning
WARNING! RISK OF INJURY!
Disconnect the appliance from
the compressed air supply.
ATTENTION!
►
Before maintenance, clean off any hazardous
substances that may have accumulated on
the tool (due to working processes) . Avoid all
skin contact with these substances . If the skin
comes into contact with hazardous dusts, this
can lead to severe dermatitis .
►
The dust and vapours produced by using
the appliance can be hazardous to health
(e .g . cause cancer, birth defects, asthma
and/or dermatitis); it is essential to carry out
a risk assessment in respect of these risks
and to implement corresponding regulatory
mechanisms .
NOTE
►
The following points must be observed
to ensure that the cleaning gun functions
perfectly and has a long service life:
■
Use only the genuine replacement parts
re commended by the manufacturer, otherwise
you could put users at risk . In doubt, contact
the Service Centre .
■
Clean the tool with a soft, dry cloth only .
■
Never use sharp or abrasive cleaning agents .
GB │ IE
│
17
■